OBJECTIVES To evaluate the safety and effectiveness of a self-closing surgical clip with an interrupted technique in left internal thoracic artery to left anterior descending artery bypass grafting. METHODS Eighty-two patients were enrolled and treated (February 2000 through August 2001) in a prospective, nonrandomized, multicenter trial. Left internal thoracic artery to left anterior descending artery anastomoses were performed in 60 off-pump coronary artery bypasses (73%), 12 conventional coronary artery bypass grafting (15%), and 10 minimally invasive direct coronary artery bypass (12%) procedures. Angiograms (64 to 383 days, mean 200 days) were obtained on 63 patients (77%). Qualitative and quantitative angiographic assessment was performed by an independent core laboratory. RESULTS The self-closing surgical clip was used for 82 left internal thoracic artery to left anterior descending artery interrupted anastomoses without the requirement for knot tying or primary suture management. Minimum left internal thoracic artery to left anterior descending artery anastomosis time was 3 minutes. There was one perioperative and one late death (both not heart related) and one reexploration for bleeding unrelated to the anastomotic site. FitzGibbon grades were as follows: A (n = 60, 95.2%), B (n = 3, 4.8%) including one kinked left internal thoracic artery, and O (n = 0, 0%). Quantitative analysis (n = 57) showed mean lumen diameters of left internal thoracic artery proximal to the anastomosis of 2.1 mm, at anastomosis of 2.0 mm, and in the left anterior descending artery distal to the anastomosis of 1.9 mm. The average ratio of the anastomosis to the left anterior descending artery diameter was 1.14 (0.45 to 1.93). Anastomotic stenosis as a percentage of average left internal thoracic artery to left anterior descending artery diameter was -2.3%, comparing favorably with results (23% to 24%) reported from the Patency, Outcomes, Economics, Minimally invasive direct coronary artery (POEM) bypass study. CONCLUSIONS The interrupted technique, facilitated by a self-closing anastomotic clip, yields favorable 6-month angiographic results when compared with other published studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Initial results on the use of mechanical devices for proximal saphenous vein graft anastomoses: a clinical and angiographic evaluation].

OBJECTIVE To report on our initial clinical experience of the utilization of a mechanical anastomotic device (MAD) to perform saphenous vein graft to aorta anastomosis. METHOD Between June 2002 and May 2003, 17 patients, including 13 male, with a mean age of 64.4 +/- 9.4 years, were selected for coronary artery bypass grafting using MAD. A total of 49 anastomoses, 19 arterial and 30 vein graf...

متن کامل

Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial).

OBJECTIVE During coronary surgery, proximal vein graft anastomoses have been performed by using an aortic partial occlusion clamp to allow for a hand-sewn anastomosis. The purpose of this multicenter, prospective, randomized trial was to evaluate the efficacy of the PAS-Port device (Cardica, Inc, Redwood City, Calif), which allows an automated proximal anastomosis to be performed without aortic...

متن کامل

U-clip anastomoses in coronary artery bypass grafting: initial clinical experience.

BACKGROUND Recent studies suggest that the U-Clip interrupted coronary artery anastomosis is superior to continuous suture. However, clinical experience with this device is limited. AIM To evaluate our initial clinical experience with the U-Clip technology. METHODS Outcomes of 59 patients undergoing isolated coronary artery bypass grafting (CABG) using U-Clips (UCs) were compared to outcome...

متن کامل

Six-month angiographic follow-up of the PAS-Port II clinical trial.

BACKGROUND The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. ...

متن کامل

Effect of progressive muscle relaxation on the vital signs and oxygenation indexes in patients under coronary artery bypass graft surgery: A triple blinded randomized clinical trial

Introduction: Cardiovascular diseases are the most common cause of death in the most countries and Iran, and are the main disability cause, those induced stress, anxiety and changes in vital signs in patients under coronary artery bypass graft (CABG) surgery. This study was conducted to determine the effect of progressive muscle relaxation on the vital signs and oxygenation indexes of patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 126 1  شماره 

صفحات  -

تاریخ انتشار 2003