Eliminating interference from heterophilic antibodies in a two-site immunoassay for creatine kinase MB by using F(ab')2 conjugate and polyclonal mouse IgG.

نویسندگان

  • H C Vaidya
  • B G Beatty
چکیده

Heterophilic antibodies interfere in two-site immunoassays. Our purpose was to screen for the samples containing heterophilic antibodies that react with mouse immunoglobulins and to use them to determine how to eliminate interference in various two-site immunoassays being developed in our laboratory. Of approximately 2600 samples screened, 81 had heterophilic antibodies. When creatine kinase MB (CKMB) concentration was measured with intact antibody conjugate in these 81 samples, 18 (22%) samples had apparent CKMB values significantly greater than values measured with Hybritech's "Tandem -E CKMB immunoenzymetric" assay and Corning agarose-gel electrophoresis. Adding up to 133 mg/L of polymerized IgG or up to 1666 mg/L polyclonal mouse IgG in the assay did not eliminate the interference in all the samples. However, adding F(ab')2 conjugate plus 40 mg/L of polymerized IgG or 83 mg/L of polyclonal mouse IgG eliminated the interference in all the samples. This approach was also effective in eliminating the interference in 15 samples containing 4.7-165.2 mg/L of human antimouse antibody (HAMA). Combined use of F(ab')2 conjugate and polyclonal mouse IgG is recommended to eliminate interference from heterophilic antibodies that react with murine immunoglobulins or HAMA in two-site murine-antibody-based assays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Falsely increased thyroid-stimulating hormone concentrations attributable to interference from human anti-mouse antibodies.

To the Editor: We describe a case of a spurious increase in serum thyroid-stimulating hormone (TSH) attributed to a circulating human anti-mouse antibody (HAMA) in a two-site mouse monoclonal antibody-based assay. A 71-year-old woman on long-term levothyroxine therapy was referred for investigation of uveitis. Her serum TSH had been maintained within the usual reference interval for more than a...

متن کامل

Production and purification of polyclonal antibody against F(ab')2 fragment of human immunoglobulin G

Antibodies are essential tools of biomedical and biochemical researches. Polyclonal antibodies are produced against different epitopes of antigens. Purified F(ab')2 can be used for animal’s immunization to produce polyclonal antibodies. Human immunoglobulin G (IgG) was purified by ion exchange chromatography method. In all stages verification method of the purified antibodies was sod...

متن کامل

The potency of immunoglobulin G fragments for inhibition of interference caused by anti-immunoglobulin antibodies in a monoclonal immunoradiometric assay for thyrotropin.

Heterophile antibodies in patients' serum may produce false increases in apparent analyte concentrations in "sandwich"-type immunoassays. Using three patients with endogenous anti-mouse IgG antibodies and a two-site mouse monoclonal assay for thyrotropin, we studied the ability of IgG fragments to block this positive interference. Mouse whole IgG and IgG Fc fragment blocked the interference vir...

متن کامل

Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies

Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...

متن کامل

Clinical and analytical evaluation of two immunoassays for direct measurement of creatine kinase MB with monoclonal anti-CK-MB antibodies.

We examined the clinical and analytical performance of two immunoassays (Becton Dickinson CK-MB; Ciba-Corning Magic Lite CK-MB) in which monoclonal anti-CK-MB antibodies are used for directly measuring creatine kinase (EC 2.7.3.2) isoenzyme MB (CK-MB) in serum, and also one electrophoretic method (Ciba-Corning). Within- and between-assay precision for both immunoassays was good at the upper ref...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 9  شماره 

صفحات  -

تاریخ انتشار 1992