How repeatable are the physiological effects of TENS?

نویسندگان

  • Miguel Fernandez-Del-Olmo
  • Maria Alvarez-Sauco
  • Giacomo Koch
  • Michele Franca
  • Gonzalo Marquez
  • Jose A Sanchez
  • Rafael M Acero
  • John C Rothwell
چکیده

OBJECTIVE Several studies suggest that transcutaneous electrical stimulation (TENS) can have a variety of effects on the central nervous system (CNS). In this study, we tried to replicate the physiological effects of TENS and to explore its effects on intracortical circuits. METHODS We used transcranial magnetic stimulation (TMS) and spinal reflex testing to examine excitability of intracortical and spinal cord circuits before and after a 30-min period of TENS over the flexor carpi radialis (FCR) muscle. We measured the amplitude of TMS-evoked muscle responses (MEP), short interval intracortical inhibition (SICI), intracortical facilitation (ICF) and cortical antagonist inhibition (CAI) in flexor and extensor carpial radialis (FCR, ECR) muscles as well as spinal reciprocal inhibition (RI) and presynaptic inhibition (PI) from ECR to FCR. RESULTS TENS had no significant effect on any of these measures apart from a reduction in median nerve induced facilitation of FCR when testing CAI. CONCLUSIONS When compared with previous studies, our results suggest that the effects of TENS are highly variable and unreliable, likely by the difficulty in defining precise parameters of stimulation in individual subjects. SIGNIFICANCE Care should be taken in assuming that effects after TENS observed in small populations of subjects will apply equally to a wider population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of vertebral column tripolar electrical stimulation with various intensities on soleus and gastrocnemius H-reflex and Mh wave recruitment curve

Abstract: To assess the effect of penetration depth of the surface tripolar electrical stimulation, Tripolar TENS was applied with different intensities (equal to sensory threshold (ST), 1.25 ST, 1.5 ST) on vertebral column of twenty healthy and three hemiplegic subjects. The cathode of TENS was laid on the T11 vertebra and anodes were put 3cm apart from cathode, longitudinally and in the anod...

متن کامل

Effects of tripolar TENS of vertebral column on slow and fast motor units: A preliminary study using H-reflex recovery curve method

Introduction: Effect of tripolar TENS of vertebral column on slow and fast motoneurons (MNs) activity of soleus muscle was previously investigated. In this study for better differentiation of the behavior of slow and fast MNs, we exploited H-reflex recovery curve recording in two muscles of soleus and lateral gastrocnemius, respectively as the representatives of slow and fast muscles. Meth...

متن کامل

Does High Frequency Transcutaneous Electrical Nerve Stimulation (TENS) Affect EEG Gamma Band Activity?

Background: Transcutaneous electrical nerve stimulation (TENS) is a noninvasive, inexpensive and safe analgesic technique used for relieving acute and chronic pain. However, despite all these advantages, there has been very little research into the therapeutic effects of TENS on brain activity. To the best of our knowledge, there is no evidence on the effect of high frequency TENS on the gamma ...

متن کامل

A comparative study on soleus H reflex parameters using vertebral column and peripheral nerve stimulation

Although low-threshold transcutaneous electrical nerve stimulation (TENS) is a modality used for control of pain, but its effect in the control of spasticity and change of excitability of a motor neuron is controversial. Therefore, this study was conducted to evaluate the effects of 15-min tripolar TENS of vertebral column and bipolar TENS of common peroneal nerve (300 µs width, 50 Hz) on synap...

متن کامل

Efficacy and Safety of TENS and Duloxetine in Patients with Painful Diabetic Neuropathy: A Single Blind Randomized Clinical Trial

Background and Objective: Both duloxetine (DLX) and transcutaneous electrical nerve stimulation (TENS) are recommended as safe and effective treatments for diabetic peripheral neuropathic pain. However, these methods have not been compared. This study aimed to compare the efficacy of treatment by DLX and TENS in diabetic neuropathy pain relief. Materials and Methods: This survey was performed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology

دوره 119 8  شماره 

صفحات  -

تاریخ انتشار 2008