ESTIMATING THE 95 th PERCENTILE OF THE PASTE- VOID SPACING DISTRIBUTION IN HARDENED CEMENT PASTE CONTAINING AIR ENTRAINMENT

نویسنده

  • K. A. Snyder
چکیده

The spacing equations of Powers, Philleo, and Pleau and Pigeon are used to estimate the uniform thickness of paste surrounding entrained air voids that is required to encompass 95 % of the air-paste system. Spacing equation accuracy is determined by comparison to the numerically exact result of Lu and Torquato. The air void system is approximated by spheres with radii from a lognormal distribution. For the systems studied here, both the Philleo and the Pleau and Pigeon equations are accurate to within approximately 10 %. The Powers spacing factor can be used to estimate the same quantity to within a factor of two, and could be made far more accurate by adjusting the result using the variance in the air void radius distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Nano-Particles on Characteristics of MetakaolinContained Cement Paste

The influences of nano-ZrO2 (NZ), nano-TiO2 (NT), nano-Fe2O3 (NF) and nano-Al2O3 (NA) additions on properties of the fresh and hardened cement paste in comparison with the fine cement paste were experimentally studied. Mini slump and flow cone tests were conducted on fresh cement pastes. Moreover the compressive and tensile strength of hardened cement paste were measured. SEM micrographs and XR...

متن کامل

Determination of the Paste to Void Proximity Distribution in Two Dimensions from a Cross-section through a Concrete Specimen

A flatbed scanner is used to collect a digital image of a polished cross-section through a concrete pavement. Image processing software is used to classify each pixel in the image as either cement paste, aggregate, or air void. The distance to the nearest air void is calculated for each pixel classified as cement paste using an accumulated cost surface algorithm. The presence of aggregate is ac...

متن کامل

EFFECT OF POLYVINYL ALCOHOL ON FLEXURAL STRENGTH AND SOME IMPORTANT PHYSICALPROPERTIES OFPORTLAND CEMENT PASTE

Abstract: This work was designed to investigate the simultaneous effect of both water-to-cement (W/C) and polymer-to-cement(P/C) ratios on flexural strength of type V Portland cement pastes containing polyvinyl alcohol. The obtained resultsconfirmed the strong effect of W/C-ratio on the effectiveness of the added polymer so that there exist optimum valuesfor both W/C and P/C-ratios. Pastes prep...

متن کامل

A rapid cyclic voltammetric method for studying cement factors affecting the corrosion of reinforced concrete

A rapid cyclic voltammetric method for studying the influence of cement factors on the corrosion of embedded iron and steel in hardened cement paste is described. The technique employs a “cement electrode” consisting of an iron or steel wire embedded in a miniature cylinder of hardened cement paste. The rapid cyclic voltammetric method is fast, reproducible, and provides information on the corr...

متن کامل

Carbon fiber reinforced cement improved by using silane-treated carbon fibers

The tensile strength of cement paste was increased by 56% and the modulus and ductility were increased by 39% by using silane-treated carbon fibers and silane-treated silica fume, relative to the values for cement paste with as-received carbon fibers and as-received silica fume. Silane treatment of fibers and silica fume contributed about equally to the strengthening. Silane treatment of fibers...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003