Evaluation of an on-line patient exposure meter in neuroradiology.
نویسندگان
چکیده
PURPOSE To assess the clinical performance and usefulness of an on-line patient exposure meter installed on a neuroradiologic biplane imaging system. MATERIALS AND METHODS A commercial on-line patient exposure meter was installed on each plane of a biplane neuroradiologic imaging system. The meter computed skin exposures on the basis of selected technique factors (tube potential and current) and information about patient location relative to the x-ray tube. Simulations were performed to measure the system accuracy with an angiographic anthropomorphic head phantom with the skin exposures measured with an ionization chamber. Skin doses were computed for 114 consecutive patients who underwent diagnostic and interventional neuroradiologic procedures. RESULTS Agreement between measured and computed skin exposures in fluoroscopy, plain radiography, and digital imaging was generally within 5% of the true skin dose. For all fluoroscopic and radiographic procedures, total median skin doses were 1.20 and 0.64 Gy for the frontal and lateral planes, respectively. In both planes, patient skin doses resulted primarily from digital subtraction angiographic acquisitions. In 29 (25%) patients, the skin dose exceeded 2.00 Gy, but no radiation-induced deterministic effects were observed. CONCLUSION An on-line patient exposure meter can provide accurate radiation skin dose data in patients undergoing diagnostic and therapeutic neuroradiologic procedures.
منابع مشابه
Estimating the radiation dose of non-radiation workers from nuclear medicine patients
Introduction: As a valuable imaging modality, Nuclear Medicine (NM) indications is raising in clinical practice. The remained portion administrated radioactive material in patients’ tissues is a critical issue, especially when the procedure is performed in hospitalized patients, where the non-radiation workers present. The aim of this study was evaluation the dose of non-radia...
متن کاملEvaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...
متن کاملEstimation of radiation dose of emergency exposure during the hospitalized 131I therapy patient
Background: The aim of the study was to estimate the radiation dose during emergency exposure to patients treated with iodine-131 during the isolation period. Materials and Methods: The dose rate from a sample of 192 patients administrated by three different radioactivity of 131I (3.7, 5.55 and 7.4 GBq) was measured, at 1 meter after 1, 24 and 48 hours post dose administration, at three d...
متن کاملInvestigation continuous noise exposure and occupational performance of the workers in the pharmaceutical industry: A Case Study in an Ampoule and Vial Production Industry
Introduction: Exposure to noise is considered as one of the most important health problems in various industries, especially pharmaceutical industry, which can ultimately lead to significant negative effects on labor force and occupational performance. The aim of this study was to investigate the relationship between continuous noise exposure and occupational performance of the workers in the p...
متن کاملEvaluation of Genotype × Environment Interaction and Grain Yield Stability of Advanced Bread Wheat Cross-bred lines by GGE Biplot Method
Extended Abstract Introduction and Objective: Investigation of the interaction of genotype × environment and identification of stable and high yielding cultivars in different environmental conditions is of great importance in plant breeding. The objectives of this study are to investigate the interaction of genotype × environment using GGE bilpot graphic method in advanced cross-breeding lines...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 203 3 شماره
صفحات -
تاریخ انتشار 1997