Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection.

نویسندگان

  • Renée A Shellhaas
  • Adina I Soaita
  • Robert R Clancy
چکیده

BACKGROUND Conventional electroencephalography remains the gold standard for the diagnosis and quantification of neonatal seizures. However, amplitude-integrated electroencephalography (aEEG) is being introduced to neonatal intensive care as an adjunct for neonatal seizure detection. OBJECTIVES This study's purpose was to determine the sensitivity of neonatal seizure detection in a single electroencephalogram channel (C3-->C4), used to simulate the raw signal from which aEEG is derived. We also aimed to determine the sensitivity of seizure detection by neonatologists by using aEEG and to establish those neonatal seizure characteristics that are associated with their correct detection by aEEG. METHODS Conventional electroencephalograms with neonatal seizures were reviewed for electroencephalogram background and neonatal seizure characteristics (site of onset, duration, and peak-to-peak amplitude). The presence, duration, and peak-to-peak amplitude of each seizure were simultaneously noted in a single electroencephalogram channel (C3-->C4). aEEGs generated from this channel were reviewed for background and seizures by 6 neonatologists with varying aEEG interpretation expertise. RESULTS A total of 851 neonatal seizures from 125 conventional electroencephalograms were analyzed. The patients' conceptional ages were 34 to 50 weeks. Because 94% of the conventional electroencephalograms had > or = 1 neonatal seizure visible in C3-->C4, and 78% of all neonatal seizures appeared in the C3-->C4 channel, the theoretical sensitivity of seizure detection in a single electroencephalogram channel was high. However, seizures were briefer and lower in amplitude in C3-->C4 compared with conventional electroencephalography. Neonatologists identified seizures in 22% to 57% of the 125 records of neonatal seizure. They detected 12% to 38% of the 851 individual seizures. Multivariate analysis revealed that the appearance of seizures in C3-->C4, neonatal seizure duration, seizure amplitude, seizure count per hour, and neonatologists' experience with aEEG interpretation all correlated with neonatal seizure detection. CONCLUSIONS Even among physicians who have extensive experience, many neonatal seizures are difficult to detect on an aEEG, especially when they are infrequent, brief, or of low amplitude.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amplitude-integrated EEG for detection of neonatal seizures: a systematic review

PURPOSE Amplitude-integrated electroencephalogram (aEEG) is being used increasingly for monitoring seizures in neonatal units. Its accuracy, compared with "the gold-standard" conventional elecroencephalogram (cEEG) is still not well established. We aimed to conduct a systematic review to evaluate the diagnostic accuracy of aEEG when compared with cEEG, for detection of neonatal seizures. METH...

متن کامل

Phenobarbital reduces EEG amplitude and propagation of neonatal seizures but does not alter performance of automated seizure detection

OBJECTIVE Phenobarbital increases electroclinical uncoupling and our preliminary observations suggest it may also affect electrographic seizure morphology. This may alter the performance of a novel seizure detection algorithm (SDA) developed by our group. The objectives of this study were to compare the morphology of seizures before and after phenobarbital administration in neonates and to dete...

متن کامل

Acute neonatal encephalopathy and seizures recurrence: A combined aEEG/EEG study

PURPOSE To evaluate amplitude-integrated EEG (aEEG) in comparison with conventional (cEEG) for the identification of electrographic seizures in neonates with acute neonatal encephalopathies. METHODS Thirty-one conventional cEEG/aEEG long-term recordings from twenty-eight newborns were reviewed in order to assess the electrographic seizure detection rate and recurrence in newborns. Two paediat...

متن کامل

The Prognostic Value of Amplitude-Integrated EEG in Full-Term Neonates with Seizures

Neonatal seizures pose a high risk for adverse outcome in survived infants. While the prognostic value of amplitude-integrated electroencephalogram (aEEG) is well established in neonates with encephalopathy and asphyxia, neonatal seizure studies focusing on the direct correlation between early aEEG measurement and subsequent neurologic outcome are scarce. In this study, the prognostic value of ...

متن کامل

In-depth performance analysis of an EEG based neonatal seizure detection algorithm

OBJECTIVE To describe a novel neurophysiology based performance analysis of automated seizure detection algorithms for neonatal EEG to characterize features of detected and non-detected seizures and causes of false detections to identify areas for algorithmic improvement. METHODS EEGs of 20 term neonates were recorded (10 seizure, 10 non-seizure). Seizures were annotated by an expert and char...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatrics

دوره 120 4  شماره 

صفحات  -

تاریخ انتشار 2007