The dynamics of D-dimer level fluctuation in patients after the cemented and cementless total hip and total knee replacement

نویسندگان

  • Piotr Bytniewski
  • Waldemar Machała
  • Leszek Romanowski
  • Wiesław Wiśniewski
  • Klaudiusz Kosowski
چکیده

INTRODUCTION The number of total hip and total knee replacement procedures performed worldwide has tended to surge in recent years, due to the combination of such factors as the increased life expectancy, improved quality of life, advances in medical technology as well as pre-operative and post-operative patient management.Numerous studies confirm that patients undergoing major orthopaedics procedures involving lower extremities, for instance total hip and total knee replacement, constitute the highest risk group for the development of post-operative venous thromboembolism (VTE), primarily manifested as deep vein thrombosis (DVT). PURPOSE The purpose of the research was to assess the dynamics of D-dimer level fluctuation during the post-operative period in patients after the cemented or cementless total hip replacement (THR) or total knee replacement (TKR), in order to prove or reject the thesis that the cemented and cementless THR or TKR affects the post-operative D-dimer levels. MATERIAL AND METHODS The study group consisted of 47 patients aged 29-82 years. Of them, 23 had the cementless THR, 12 subjects had the cemented THR and another 12 patients had the TKR. All of the patients performed to measure the concentration of D-dimers in the peri-operative period at predetermined time points. For the peri-operative period was adopted from time 1 day before surgery to 10-day hospitalization. The subarachnoid block (SAB) was performed in all patients. RESULTS The distribution of D-dimer values throughout the entire post-operative period (up to 10th post-operative day) followed the sinusoid pattern with two peaks in all patients. It was not specific in any group. CONCLUSIONS 1. The D-dimer level almost doubles during the post-operative period in patients after THR or TKR.2. Higher level of D-dimers in post-operative period in the research group of patients does not relate to higher risk of thromboembolic disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Knee and Hip Joint Replacement Surgery in a Patient with Ochronotic Arthropathy: Surgical Tips

Ochronosis or black joints disorder is a rare autosomal recessive disorder caused by deficiency of homogentisic acidoxidase. Orthopaedic manifestations are common and mostly involve spine and large joints such as knee and hip.Arthropathy is progressive and will eventually leads to arthroplasty. Not being familiar with this disorder might lead todevastating complications. We present a 57 year-ol...

متن کامل

[Total hip replacement in patients with ankylosing spondylitis.].

The authors present their experience with total hip replacement in patients with ankylosing spondylitis. In the period of 1985-1997 they performed in total 66 total hip replacements in 41 patients. Of the total number of the used implants 24 were fully cemented (the average follow-up - 13 years), 3 were hybrid and 39 cementless (the average follow-up - 6 years). The results of total hip replace...

متن کامل

Revision Rates after Primary Hip and Knee Replacement in England between 2003 and 2006

BACKGROUND Hip and knee replacement are some of the most frequently performed surgical procedures in the world. Resurfacing of the hip and unicondylar knee replacement are increasingly being used. There is relatively little evidence on their performance. To study performance of joint replacement in England, we investigated revision rates in the first 3 y after hip or knee replacement according ...

متن کامل

A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacement. Ten-year survival analysis.

We have carried out a long-term survival analysis of a prospective, randomised trial comparing cemented with cementless fixation of press-fit condylar primary total knee replacements. A consecutive series of 501 replacements received either cemented (219 patients, 277 implants) or cementless (177 patients, 224 implants) fixation. The patients were contacted at a mean follow-up of 7.4 years (2.7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014