The necessity of identifying the basal glucose set-point in the IVGTT for patients with Type 2 Diabetes

نویسندگان

  • Nor Azlan Othman
  • Paul D Docherty
  • Jeremy D Krebs
  • Damon A Bell
  • J Geoffrey Chase
چکیده

BACKGROUND The model-based dynamic insulin sensitivity and secretion test (DISST) uses fasting glucose (G 0 ) as the basal glucose (G B ) concentration when assessing insulin sensitivity (SI). However, this model was developed in a healthy, normoglycaemic cohort. We sought to determine the suitability the DISST model has for individuals with established type 2 diabetes (T2D). METHODS 14 participants with established T2D were recruited to take part in a dietary intervention study. Insulin-modified intravenous glucose tolerance tests (IM-IVGTT) were undertaken at week 0, 12 and 24 and were used with DISST model to identify G B . A total of 36 tests were conducted across 12 participants throughout the study. Measured G 0 and identified G B values were compared using a Kolmogorov-Smirnov (KS) and signed rank (RS) test for the cohort. RESULTS There were significant differences between the G 0 and identified G B values in this cohort (prs and pks < 0.0001), although both values were well correlated (R = 0.70). The residual plot demonstrates that the modified model captures the behaviour of the participants more accurately than the original model. CONCLUSIONS This analysis has shown that G B is an important variable for modelling the glycaemic behaviour in T2D. These findings suggest that the original DISST model, while appropriate for normoglycaemic cohorts, needs to model basal glucose level as a variable for assessing individuals with established T2D.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence and Risk Factors of Diabetes, Pre-Diabetes and Metabolic Syndrome in First-Degree Relatives of Patients with Type II Diabetes

Background & Aims: The aim of this study was to estimate the prevalence and risk factors for diabetes, pre-diabetes and metabolic syndrome in first-degree relatives(FDRs) of patients with type 2 diabetes. Methods: In a cross-sectional study between 2003 and 2005, 3228 of first-degree relatives of patients with type 2 diabetes (841 men and 2387 women) from Isfahan Endocrine and Metabolism Resear...

متن کامل

Effect of Date and Raisin Snacks on Glucose Response in Type 2 Diabetes

Background and Objectives: Snacks are important parts of diabetes patients’ diet. The aim of the present study was to evaluate the effects of moderate amounts of dates and raisins, as nutritious snacks, on blood glucose, and to compare these effects with sugar in patients with type 2 diabetes. Materials and Methods: This crossover clinical trial was performed on 15 patients with type 2 diabete...

متن کامل

The Effect of Resistance Exercise on Blood Glucose, Insulin and Insulin resistance in Iranian Patients with Type II Diabetes: A Systematic Review and Meta-Analysis

Objective: Resistance exercise is recommended as effective treatments for people with type 2 diabetes. However, the impact of this mode of exercise on blood glucose, insulin and insulin resistance in Iranian's type 2 diabetic patients is unclear. We conducted a systematic review of the literature for the effect of resistance exercise training on these clinical markers in Iranian's type 2 diabet...

متن کامل

Designing a glycemic control strategy to maintain glucose homeostasis and prevent hypoglycemia for subjects with type 1 diabetes

This paper presents using the fractional PImDn controller module which manipulates insulin infusion rate to maintain normoglycemia in subjects with type 1 diabetes. To prevent severe hypoglycemia, a conventional proportional controller is used to regulate glucagon infusion rate when the blood glucose levels fall below a threshold. Two sets of controller parameters are obtained and evaluated. Fo...

متن کامل

Identifying high and low serum-ascites albumin gradient in ascitic fluid by the point of care dipstick test

Objective: To evaluate the capability of ascitic fluid dipstick results for pH, glucose, and protein in order to predict a low serum-ascites albumin gradient (SAAG) at the bedside of the patient in the emergency department (ED). Methods: This prospective cross-sectional study was conducted during one year in the ED of Afzalipour hospital in Kerman, Iran. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2015