Validating a Stability Indicating HPLC Method for Kinetic Study of Cetirizine Degradation in Acidic and Oxidative Conditions
نویسندگان
چکیده
A stability indicating High-Performance Liquid Chromatography (HPLC) method was validated and used to study the degradation of cetirizine dihydrochloride in acidic and oxidative conditions. The separation was carried out on a Symmetry C18 column and a mixture of 50 mM KH2PO4 and acetonitrile (60:40 v/v, pH = 3.5) was used as the mobile phase. The method was linear over the range of 1-20 μg/mL of cetirizine dihydrochloride (r(2) > 0.999) and the within-day and between-day precision values were less than 1.5%. The results showed that cetirizine dihydrochloride was unstable in 2 M HCl and 0.5% H2O2. The kinetics of the acidic degradation showed a pseudo-first-order reaction in the temperature range of 70-90°C. In addition, the kinetics of hydrogen peroxide mediated degradation was pseudo-first-order in the temperature range of 50-80°C.
منابع مشابه
Validating a Stability Indicating HPLC Method for Kinetic Study of Cetirizine Degradation in Acidic and Oxidative Conditions
A stability indicating High-Performance Liquid Chromatography (HPLC) method wasvalidated and used to study the degradation of cetirizine dihydrochloride in acidic and oxidativeconditions. The separation was carried out on a Symmetry C18 column and a mixture of 50 mMKH2PO4 and acetonitrile (60:40 v/v, pH = 3.5) was used as the mobile phase. The method waslinear over the range of 1-20 μg/mL of ce...
متن کاملValidating a Stability Indicating HPLC Method for Kinetic Study of Cetirizine Degradation in Acidic and Oxidative Conditions
A stability indicating High-Performance Liquid Chromatography (HPLC) method wasvalidated and used to study the degradation of cetirizine dihydrochloride in acidic and oxidativeconditions. The separation was carried out on a Symmetry C18 column and a mixture of 50 mMKH2PO4 and acetonitrile (60:40 v/v, pH = 3.5) was used as the mobile phase. The method waslinear over the range of 1-20 μg/mL of ce...
متن کاملA Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms
Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...
متن کاملA Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms
Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...
متن کاملDevelopment, Validation and Application of RP-HPLC Method: Simultaneous Determination of Antihistamine and Preservatives with Paracetamol in Liquid Formulations and Human Serum
In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2013