Comparison of two different modes for noninvasive mechanical ventilation in chronic respiratory failure: volume versus pressure controlled device.

نویسندگان

  • B Schönhofer
  • M Sonneborn
  • P Haidl
  • H Böhrer
  • D Köhler
چکیده

The most commonly used mode of noninvasive mechanical ventilation (NMV) is volume-controlled intermittent positive pressure ventilation (IPPV). Pressure support ventilation has recently become increasingly popular, but its merits have not been clearly defined. In an open, nonrandomized follow-up study, we evaluated two modes of NMV, volume-controlled (IPPV) and pressure-controlled ventilation (PCV) over 6 months in 30 consecutive patients (24 males and 6 females, aged 49 +/- 19 yrs) with chronic respiratory failure (CRF). The baseline assessments comprised both physiological and subjective data. In all cases, nasal IPPV was initially administered for 1 month, followed by a second month of nasal PCV. Thereafter, responders or nonresponders to PCV were defined according to the patients' subjective symptom score and/or the recurrence of hypercapnia. During the IPPV phase, in all but two patients the subjective and objective parameters improved significantly. During the following 1 month PCV phase, stabilization was maintained in 18 patients ("responders"), while 10 patients were defined as "nonresponders". In nonresponders, hypercapnia increased (arterial carbon dioxide tension (Pa,CO2): 5.7 +/- 0.4 to 6.6 +/- 0.5 kPa; p < 0.05) and symptom scores decreased. Compared with responders, nonresponders had a lower mean nocturnal arterial oxygen saturation (Sa,O2) (p < 0.05) and a higher daytime Pa,CO2 (p < 0.05) at baseline. We con clude that the majority of patients suffering from chronic respiratory failure who are initially satisfactorily ventilated with intermittent positive pressure ventilation may also be adequately maintained with pressure-controlled ventilation. However, there is a subgroup with more severe chronic respiratory failure at baseline, in whom pressure-controlled ventilation is inadequate. After 4 weeks of treatment with pressure-controlled ventilation, the subjective scores and the arterial carbon dioxide tension values reliably distinguished between long-term responders and nonresponders to pressure-controlled ventilation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficiency and outcome of non-invasive versus invasive positive pressure ventilation therapy in respiratory failure due to chronic obstructive pulmonary disease

Background: Application noninvasive ventilation in the patients with exacerbation of chronic obstructive pulmonary disease (COPD) reduced mortality. This case-control study was designed to compare efficiency and outcome of non-invasive (NIV) versus invasive positive pressure ventilation (IPPV) in respiratory failure due to COPD Methods: The patients were assigned to NIV or IPPV intermittantl...

متن کامل

Early Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial

Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...

متن کامل

Early Effectiveness of Noninvasive Positive Pressure Ventilation on Right Ventricular Function in Chronic Obstructive Pulmonary Disease Subjects with Acute Hypercapnic Respiratory Failure

Introduction: Noninvasive positive pressure ventilation (NIPPV) has become an integral tool in the management of acute hypercapnic respiratory failure (AHRF) in chronic obstructive pulmonary disease (COPD). This study was performed to evaluate the early effects of NIPPV on pulmonary artery pressure (PAP), serum N-terminal pro BNP (NT-proBNP), and ventilatory parameters in the COPD patients with...

متن کامل

New modalities for non-invasive positive pressure ventilation: A review article

Efficiency of non-invasive positive pressure ventilation in the treatment of respiratory failure has been shown in many published studies. In this review article, we introduced new modalities of non-invasive ventilation (NIV), clinical settings in which NIV can be used and a practical summary of the latest official guidelines published by the European Respiratory Clinical Practice. Clinical tri...

متن کامل

Volume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial

Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 1997