Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography

نویسندگان

  • J. Ender
  • S. Eibel
  • C. Mukherjee
  • D. Mathioudakis
  • M.A. Borger
  • S. Jacobs
  • F.W. Mohr
  • V. Falk
چکیده

AIMS We sought to investigate the additional value of real-time three-dimensional transoesophageal echocardiography (RT 3D TOE)-guided sizing for predicting annuloplasty ring size during mitral valve repair. METHODS AND RESULTS In 53 patients undergoing elective mitral valve repair, an RT 3D TOE was performed pre- and post-operatively. The digitally stored loops were imported into a software for mitral valve assessment. The annuloplasty ring size was predicted by superimposing computer-aided design (CAD) models of annuloplasty rings onto Live 3D zoom loops, measurement of the intercommissural distance, or the height of the anterior mitral leaflet. The surgeon implanted the annuloplasty ring according to the usual surgical technique and was blinded to the echocardiographic measurement results. Pre-operative correlation between the selected ring size with mitral valve assessment and the actual implanted annuloplasty ring size was 0.91. The correlation for measurement of the intercommissural distance was 0.55 and for measurement of the height of the anterior mitral leaflet 0.75. The post-operative correlation with the actual implanted ring size was 0.96 for mitral valve assessment, 0.92 for intercommissural distance, and 0.79 for the anterior mitral leaflet height. CONCLUSION Superimposition of annuloplasty ring CAD models on the Live 3D zoom loops of the mitral valve using mitral valve assessment is superior to two-dimensional measurements of the intercommissural distance or the height of the anterior mitral leaflet in predicting correct annuloplasty ring size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence.

OBJECTIVES This study sought to assess the use of real-time (RT) 3-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) in the evaluation of post-operative mitral valve dehiscence. BACKGROUND Mitral valve replacement or repair may be complicated by post-operative dehiscence of the valve or annuloplasty ring resulting in clinically significant mitral regurgitation or hemol...

متن کامل

Bioptome injury to the tricuspid valve in a cardiac allograft recipient visualized by three-dimensional echocardiography.

1999;88:1205–12. 7. Troianos CA, Konstadt S. Evaluation of mitral regurgitation. Semin Cardiothorac Vasc Anesth 2006;10:67–71. 8. Cook RC, Nifong LW, Lashley GG, Duncan RA, Campbell JA, Law YB et al. Echocardiographic measurements alone do not provide accurate non-invasive selection of annuloplasty band size for robotic mitral valve repair. J Heart Valve Dis 2006;15:524–7. 9. Ender J, Koncar-Ze...

متن کامل

Value of transesophageal echocardiography (TEE) guidance in minimally invasive mitral valve surgery.

The role of intraoperative transesophageal echocardiography (TEE) has increased tremendously since its first use in 1979. Today intraoperative TEE is a class I indication for surgical mitral valve reconstruction for evaluation of mitral valve pathology, graduation of mitral regurgitation and detection of potential risk factors as well as post-repair assessment. Real-time three-dimensional TEE o...

متن کامل

Surgery for Valvular Heart Disease Three-Dimensional Echocardiographic Analysis of Mitral Annular Dynamics Implication for Annuloplasty Selection

Background—Proponents of flexible annuloplasty rings have hypothesized that such devices maintain annular dynamics. This hypothesis is based on the supposition that annular motion is relatively normal in patients undergoing mitral valve repair. We hypothesized that mitral annular dynamics are impaired in ischemic mitral regurgitation and myxomatous mitral regurgitation. Methods and Results—A Ph...

متن کامل

Three-dimensional echocardiographic analysis of mitral annular dynamics: implication for annuloplasty selection.

BACKGROUND Proponents of flexible annuloplasty rings have hypothesized that such devices maintain annular dynamics. This hypothesis is based on the supposition that annular motion is relatively normal in patients undergoing mitral valve repair. We hypothesized that mitral annular dynamics are impaired in ischemic mitral regurgitation and myxomatous mitral regurgitation. METHODS AND RESULTS A ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011