Mechanical ventilation of the premature neonate.

نویسندگان

  • Melissa K Brown
  • Robert M DiBlasi
چکیده

Although the trend in the neonatal intensive care unit is to use noninvasive ventilation whenever possible, invasive ventilation is still often necessary for supporting pre-term neonates with lung disease. Many different ventilation modes and ventilation strategies are available to assist with the optimization of mechanical ventilation and prevention of ventilator-induced lung injury. Patient-triggered ventilation is favored over machine-triggered forms of invasive ventilation for improving gas exchange and patient-ventilator interaction. However, no studies have shown that patient-triggered ventilation improves mortality or morbidity in premature neonates. A promising new form of patient-triggered ventilation, neurally adjusted ventilatory assist (NAVA), was recently FDA approved for invasive and noninvasive ventilation. Clinical trials are underway to evaluate outcomes in neonates who receive NAVA. New evidence suggests that volume-targeted ventilation modes (ie, volume control or pressure control with adaptive targeting) may provide better lung protection than traditional pressure control modes. Several volume-targeted modes that provide accurate tidal volume delivery in the face of a large endotracheal tube leak were recently introduced to the clinical setting. There is ongoing debate about whether neonates should be managed invasively with high-frequency ventilation or conventional ventilation at birth. The majority of clinical trials performed to date have compared high-frequency ventilation to pressure control modes. Future trials with premature neonates should compare high-frequency ventilation to conventional ventilation with volume-targeted modes. Over the last decade many new promising approaches to lung-protective ventilation have evolved. The key to protecting the neonatal lung during mechanical ventilation is optimizing lung volume and limiting excessive lung expansion, by applying appropriate PEEP and using shorter inspiratory time, smaller tidal volume (4-6 mL/kg), and permissive hypercapnia. This paper reviews new and established neonatal ventilation modes and strategies and evaluates their impact on neonatal outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence and risk factors of pneumothorax in premature low birth weight infants under mechanical ventilation

Objective: pulmonary air-leakage especially pneumothorax (ptx), is a severe complication in neonates. The aim of this study was to assess the predisposing factors and frequency of ptx among the low birth weight (LBW) premature infants, under mechanical ventilation. Methods: This cross sectional study was performed in 121 LBW intubated premature infants at neonatal intensive care unit of a child...

متن کامل

A novel, versatile valved holding chamber for delivering inhaled medications to neonates and small children: laboratory simulation of delivery options.

BACKGROUND Delivery of bronchodilator to infants and small children from a pressurized metered-dose inhaler with valved holding chamber (pMDI-VHC) is limited by airway narrowness, short respiratory cycle time, and small tidal volume (V(T)). There is a need for a versatile, efficient VHC, given the variety of treatment modalities. METHODS We tested the AeroChamber Mini VHC (the internal geomet...

متن کامل

Comparison of the Therapeutic Effects of Bubble CPAP and Ventilator CPAP on Respiratory Distress Syndrome in Premature Neonates

Background: Respiratory distress syndrome is one of the main complications associated with low birth weight, and a main cause of mortality in premature neonates. The present study aimed to compare the efficacy of ventilator continuous positive airway pressure (CPAP) and bubble CPAP in the treatment of respiratory distress syndrome (RDS) in premature neonates. Methods: This randomized controlled...

متن کامل

Evaluation of Troponin-T level in Neonate with Mechanical Ventilation

Introduction: Troponin- T is the best biological marker of heart injuries, that isn’t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...

متن کامل

Investigation of oxygenation in premature infants under mechanical ventilation in supine position compare to side lying

Abstract Introduction: Changing position is an important aspect within nursing care. Prone positioning amongst premature infants could improve their oxygenation compared to supine position. Side lying position leads to developed support between premature infants, however there is few studies about effects of this position on premature infants 'oxygenation. Objective: This study was conduc...

متن کامل

Survival after pulmonary haemorrhage in idiopathic respiratory distress syndrome of the newborn.

Pulmonary haemorrhage is a commonly fatal condition which may complicate mechanical ventilation of the premature neonate with the respiratory distress syndrome (RDS). The survival of one such patient is recorded.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 56 9  شماره 

صفحات  -

تاریخ انتشار 2011