A Virtual EXV Mass Flow Sensor for Applications With Two-Phase Flow Inlet Conditions

نویسندگان

  • Christian K. Bach
  • Eckhard A. Groll
  • James E. Braun
  • Ray W. Herrick
چکیده

In conventional vapor compression systems, electronic expansion valves (EXVs) are used for refrigerant flow control. Subcooled refrigerant enters the expansion device and is expanded to the evaporation pressure while the valve opening is modified to achieve the desired mass flowrate. The relationship between the inlet and outlet conditions, the opening, and the mass flowrate has been extensively studied, e.g. by Park et al. (2007) and appropriate empirical correlations have been developed. However, for certain operating conditions (e.g. low refrigerant charge) or applications that generally have two-phase inlet conditions (e.g. balancing valves used in a hybrid control scheme as proposed by Kim et al. (2008)), these correlations are not applicable, since even low inlet vapor fractions lead to a significant reduction of the valve mass flowrate at a given opening. This paper proposes a continuous correlation that can be used for both two-phase and subcooled valve inlet conditions. The benefit of the continuity is that there is a smooth transition between subcooled and two-phase inlet conditions, which is essential for control and simulation purposes. The new correlation employs the Buckingham-Pi theorem as proposed by Buckingham (1914). The selected dimensionless Pi-groups describe opening of the valve, subcooling, inlet and outlet pressures, driving pressure difference across the valve, inlet density, surface tension, and viscosity. The data that was used to determine the coefficients of the correlation was taken on a dedicated valve test stand, which was sized for the per-circuit capacity of a typical 5-ton R410A heat pump and a 3-ton R404A large room cooling system. The purpose of these tests was mainly to map the valves for the low pressure drops, high inlet qualities and large valve openings that occur when they are used as balancing valves in a hybrid control approach. Two commercially available valves of different rated capacity were tested. Due to the much higher valve capacity for subcooled inlet conditions, valve openings of less than 5% occurred in that case. This led to an accuracy of the correlation for these points that is less than what typically can be found for correlations with subcooled inlet conditions in the open literature. However, for two-phase flow inlet conditions, the resulting RMS of 1.0 g/s for the 8-PI correlation is sufficiently small to use the approach for estimating the refrigerant mass flow and using the EXV as a virtual flow sensor. The limitations of this approach in practical applications, as well as possible applications in fault detection and diagnostics are shown for application as balancing valves within a 5-ton R410A heat pump and a 3-ton R404A large room cooling system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Response Analysis of the Planar and Tubular Solid Oxide Fuel Cells to the Inlet Air Mass Flow Rate Variation

The purpose of present study is to investigate the dynamic response of two conventional types of solid oxide fuel cells to the inlet air mass flow rate variation. A dynamic compartmental model based on CFD principles is developed for two typical planar and tubular SOFC designs. The model accounts for transport processes (heat and mass transfer), diffusion processes, electrochemical processes, a...

متن کامل

Drag coefficient and strouhal number analysis of a rectangular probe in a two-phase cross flow

In some case of laboratory and industrial applications, various kind of measurement instruments must be placed in a conduit, in which multiphase fluid flows. Vortex shedding for any immersed body in flow field is created with a frequency, which according to flow conditions such as flow rates, geometry of body, etc. may be constant or variable. Failure may happen, if this frequency is close to o...

متن کامل

The Overall Heat Transfer Characteristics of a Double Pipe Heat Exchanger: Comparison of Experimental Data with Predictions of Standard Correlations

The single-phase flow and thermal performance of a double pipe heat exchanger are examined by experimental methods. The working fluid is water at atmospheric pressure. Temperature measurements at the inlet and outlet of the two streams and also at an intermediate point half way between the inlet and outlet is made, using copper-constantan thermocouple wires. Mass flow rates for each stream are ...

متن کامل

Numerical modeling of three-phase flow through a Venturi meter using the LSSVM algorithm

One of the challenging problems in the Oil & Gas industry is accurate and reliable multiphase flow rate measurement in a three-phase flow. Application of methods with minimized uncertainty is required in the industry. Previous developed correlations for two-phase flow are complex and not capable of three-phase flow. Hence phase behavior identification in different conditions to designing and mo...

متن کامل

Virtual Refrigerant Mass Flow and Power Sensors for Variable-Speed Compressors

The use of variable-speed compressors in heat pumps and air conditioners has increased in recent years in order to improve comfort and energy efficiency. At the same time, there is a trend towards embedding more sensors in this type of equipment to facilitate real-time energy monitoring and diagnostics. Although compressor mass flow rate and power consumption are useful indices for performance ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012