Correction of the influence of baseline artefacts and electrode polarisation on dielectric spectra.

نویسندگان

  • J E Yardley
  • R Todd
  • D J Nicholson
  • J Barrett
  • D B Kell
  • C L Davey
چکیده

The deconvolution of biological dielectric spectra can be difficult enough with artefact-free spectra but is more problematic when machine baseline artefacts and electrode polarisation are present as well. In addition, these two sources of anomalies can be responsible for significant interference with dielectric biomass measurements made using one- or two-spot frequencies. The aim of this paper is to develop mathematical models of baseline artefacts and electrode polarisation which can be used to remove these anomalies from dielectric spectra in a way that can be easily implemented on-line and in real-time on the Biomass Monitor (BM). We show that both artefacts can be successfully removed in solutions of organic and inorganic ions; in animal cell and microbial culture media; and in yeast suspensions of varying biomass. The high quality of the compensations achieved were independent of whether gold and platinum electrodes were used; the electrode geometry; electrode fouling; current density; the type of BM; and of whether electrolytic cleaning pulses had been applied. In addition, the calibration experiments required could be done off-line using a simple aqueous KCl dilution series with the calibration constants being automatically calculated by a computer without the need for user intervention. The calibration values remained valid for a minimum of 3 months for the baseline model and indefinitely for the electrode polarisation one. Importantly, application of baseline correction prior to polarisation correction allowed the latter's application to the whole conductance range of the BM. These techniques are therefore exceptionally convenient to use under practical conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Characterization of Miconazole effects on Mice fetus liver tissue using FTIR-MSP

Azole agents especially Miconazole are widely used even during pregnancy as antifungal agents. The aim of this study was to assess the usefulness of FTIR Micro-Spectroscopy for discriminating of Miconazole treated liver tissue from control liver tissue. The mice were injected with Miconazole (60 mg/Kg) on gestation day 9 and they were dissected on pregnancy day 15. The fetus fixed, dehydrated a...

متن کامل

A Numerical Study of the Sour Gas Reforming in a Dielectric Barrier Discharge Reactor

In this paper, using a one-dimensional simulation model, the reforming process of sour gas, i.e. CH4, CO2, and H2S, to the various charged particles and syngas in a dielectric barrier discharge (DBD) reactor is studied. An electric field is applied across the reactor radius, and thus a non-thermal plasma discharge is formed within the reactor. Based on the space...

متن کامل

Characterization of Miconazole effects on Mice fetus liver tissue using FTIR-MSP

Azole agents especially Miconazole are widely used even during pregnancy as antifungal agents. The aim of this study was to assess the usefulness of FTIR Micro-Spectroscopy for discriminating of Miconazole treated liver tissue from control liver tissue. The mice were injected with Miconazole (60 mg/Kg) on gestation day 9 and they were dissected on pregnancy day 15. The fetus fixed, dehydrated a...

متن کامل

Pongamia pinnata Plant Seed Oil as Dielectric Fluid for Electro Discharge Machining Process

Electro Discharge Machining (EDM) is a noticeable machining practice among created unconventional machining procedures for intricate, complex profiles in "hard to machine" materials, similar to heat-treated steels, composites, superalloys, ceramics, composites, carbides, and so on. In EDM, the material expulsion of the cathode is accomplished through precise controlled electric discharge (the s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bioelectrochemistry

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 2000