Computer-generated fMRI phantoms with motion-distortion interaction.

نویسندگان

  • Ning Xu
  • J Michael Fitzpatrick
  • Yong Li
  • Benoit M Dawant
  • David R Pickens
  • Victoria L Morgan
چکیده

As an extension of previous work on computer-generated phantoms, more accurate, realistic phantoms are generated by integrating image distortion and signal loss caused by susceptibility variations. With the addition of real motions and activations determined from actual functional MRI studies, these phantoms can be used by the fMRI community to assess with higher fidelity pre-processing algorithms such as motion correction, distortion correction and signal-loss compensation. These phantoms were validated by comparison to real echo-planar images. Specifically, studies have shown the effects of motion-distortion interactions on fMRI. We performed motion correction and activation analysis on these phantoms based on a block paradigm design using SPM2, and the results demonstrate that interactions between motion and distortion affect both motion correction and activation detection and thus represent a critical component of phantom generation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Realistic Computer Generated fMRI Phantoms with Motion Correlated Susceptibility Artifacts

Figure 2. Comparision of activation maps with and without susceptibility artifacts from SPM2. (a) true activation map. (b) activation map detected from phantoms without susceptibility artifacts. (c) activation map detected from phantoms with susceptiblity artifacts. More false activations are obsevered in (c), and the detected activation regions are spatially shifted relative to the true map (a...

متن کامل

Comparison of fMRI statistical software packages and strategies for analysis of images containing random and stimulus-correlated motion

The objectives of this study were to use computer-generated phantoms containing real subject motion to: (1) compare the sensitivity of four commonly used fMRI software packages and (2) compare the sensitivity of three statistical analysis strategies with respect to motion correction. The results suggest that all four packages perform similarly in fMRI statistical analysis with SPM2 having sligh...

متن کامل

Suppressing Respiration Effects when Geometric Distortion Is Corrected Dynamically by Phase Labeling for Additional Coordinate Encoding (PLACE) during Functional MRI

Echo planar imaging (EPI) suffers from geometric distortions caused by magnetic field inhomogeneities, which can be time-varying as a result of small amounts of head motion that occur over seconds and minutes during fMRI experiments, also known as "dynamic geometric distortion". Phase Labeling for Additional Coordinate Encoding (PLACE) is a promising technique for geometric distortion correctio...

متن کامل

Image distortion correction in fMRI: A quantitative evaluation.

A well-recognized problem with the echo-planar imaging (EPI) technique most commonly used for functional magnetic resonance imaging (fMRI) studies is geometric distortion caused by magnetic field inhomogeneity. This makes it difficult to achieve an accurate registration between a functional activation map calculated from an EPI time series and an undistorted, high resolution anatomical image. A...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 25 10  شماره 

صفحات  -

تاریخ انتشار 2007