Chord distributions across 3D digital images of a human thoracic vertebra.
نویسندگان
چکیده
Radiation dose estimates to the trabecular region of the skeleton are of primary importance due to recent advancements in nuclear medicine. Establishing methods for accurately calculating dose in these regions is difficult due to the complex microstructure of this anatomic site and the typical ranges of beta-particles in both bone and marrow tissues. At the present time, models of skeletal dosimetry used in clinical medicine rely upon measured distributions of straight-line path lengths (chord lengths) through bone and marrow regions. This work develops a new three-dimensional, digital method for acquiring these distributions within voxelized images. In addition, the study details the characteristics of measuring chord distributions within digital images and provides a methodology for avoiding undesirable pixel or voxel effects. The improved methodology has been applied to a digital image (acquired via NMR microscopy) of the trabecular region of a human thoracic vertebra. The resulting chord-length distributions across both bone trabeculae and bone marrow cavities were found to be in general agreement with those measured in other studies utilizing different methods. In addition, this study identified that bone and marrow space chord-length distributions are not statistically independent, a condition implicitly assumed within all current skeletal dosimetry models of electron transport. The study concludes that the use of NMR microscopy combined with the digital measurement techniques should be used to further expand the existing Reference Man database of trabecular chord distributions to permit the development of skeletal dosimetry models which are more age and gender specific.
منابع مشابه
Beta-particle dosimetry of the trabecular skeleton using Monte Carlo transport within 3D digital images.
Presently, skeletal dosimetry models utilized in clinical medicine simulate electron path lengths through skeletal regions based upon distributions of linear chords measured across bone trabeculae and marrow cavities. In this work, a human thoracic vertebra has been imaged via nuclear magnetic resonance (NMR) spectroscopy yielding a three-dimensional voxelized representation of this skeletal si...
متن کاملInfluences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom
Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملDesign of homogeneous and heterogeneous human equivalent thorax phantom for tissue inhomogeneity dose correction using TLD and TPS measurements
Background: The purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the Treatment Planning Systems (TPS) calculated values for different lung treatment dosimetery. It is compared with Thermoluminescent Dosimeter (TLD) measurement. Materials and Methods: Homogeneous and heterogeneous tho...
متن کاملCompression of 2-D Biomedical Images
On a daily basis, large amounts of medical images are acquired using 2D acquisition imaging systems (e.g., vertebra and lung digital X rays, mammography). Moreover, it is possible to compress temporal sequences (i.e. 2D+t), volume sequences (i.e. 3D) or even spatio-temporal sequences (i.e. 3D+t) by encoding each image separately and independently of all others (i.e. in clinical routine, physici...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 28 7 شماره
صفحات -
تاریخ انتشار 2001