A sensitive manual enzyme immunoassay for thyroxine.
نویسندگان
چکیده
We describe an immunoassay for thyroxine in serum. In the assay specific antibody covalently bonded to latex particles is used, along with horseradish peroxidase as the label, and o-phenylenediamine as the chromogen. The flexible protocol is designed for manual execution. Performance is similar to that of the highest-sensitivity thyroxine radioimmunoassays. Results correlate well with radioimmunoassay (r = 0.99, slope = 0.93, y-intercept = 2.4 microgram/liter for 201 samples) and an automated enzyme immunoassay (r = 0.97, slope = 0.99, y-intercept = 4.7 coefficients of variation are less than 7.2% over the entire useful range of the assay (20--240 microgram/liter). The limit of detection is less than 94 pg/tube at 20 microgram/liter. Only D-thyroxine is known to interfere with serum assays. This assay has no discernible protein effect from 40 to 80 g of protein per liter, unlike many thyroxine radioimmunoassays. Serum preservatives known to be peroxidase inhibitors do not adversely affect assay performance because of the 56-fold dilution in the final assay mixture. Hemolyzed serum and EDTA-treated plasmas are unsuitable for this assay.
منابع مشابه
Evaluation of the manual enzyme immunoassay (EMIT) procedure for determination of serum thyroxine.
Our experience with the determination of thyroxine (T4) in serum using a homogeneous enzyme immunoassay technique (EMIT, Syva Corp.) is reported. The intra-assay precision of the EMIT Manual Thyroxine Assay was investigated with 2 different calibrator concentrations and showed coefficients of variation varying from 5--2% for thyroxine concentrations of 40 and 120 micrograms/l thyroxine respecti...
متن کاملContinuous-flow enzyme immunoassay for thyroxine in serum.
We have evaluated a fully automated thyroxine assay involving the use of a homogeneous enzyme assay and a Technicon AutoAnalyzer II continuous flow system. Comparison by regression analysis with a thyroxine radioimmunoassay kit method gave a slope of 0.82 and a y-intercept of 7.81 micrograms/L (SE 0.86 microgram/L, r = 0.95). Within-run precision yielded CVs of 1.0-6.1%, between-day CVs were 2....
متن کاملEnzyme immunoassay of serum thyroxine with the "Autochemist" multichannel analyzer.
We have modified the homogeneous enzyme immunoassay of thyroxine and have adapted it to the AutoChemist. Both enzyme immunoassay and radioimmunnoassay procedures were performed on 2016 patients' sera on which thyroxine determinations had been ordered. We find the automated enzyme immunoassay to be precise and accurate, and for the first time it permits total automation of an immunoassay on a mu...
متن کاملDevelopment of a highly sensitive and selective microplate chemiluminescence enzyme immunoassay for the determination of free thyroxine in human serum
A microplate chemiluminescence enzyme immunoassay (CLEIA) with high sensitivity, selectivity and reproducibility was developed for the determination of free thyroxine (FT4) in human serum. A competitive assay has been utilized with horseradish peroxidase (HRP) labeled thyroxine analog in the chemiluminescence (CL) detection. The CL signal produced by the emission of photons from luminol was dir...
متن کاملEvaluation of homogeneous enzyme immunoassay of serum thyroxine with the Gilford 3500 analyzer.
I evaluated homogeneous enzyme immunoassay (EMIT) of serum thyroxine with the Gilford 3500 analyzer. The samples are pretreated before quantitation on the Gilford 3500; the procedure thereafter is entirely mechanized. Forty-four samples may be analyzed per run. Precision and accuracy are good, and results correlate well with those by radioimmunoassay.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 10 شماره
صفحات -
تاریخ انتشار 1978