A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123.

نویسندگان

  • A Tsuji
  • A Kojima
  • M Matsumoto
  • Y Oyama
  • S Tomiguchi
  • T Kira
  • Y Takagi
  • O Shimomura
  • M Takahashi
چکیده

We have developed a new method of crosstalk correction in simultaneous dual-isotope imaging with Tl-201 and I-123 by using crosstalk ratios and a blurring filter. Single isotope myocardial studies (10 for Tl-201 and 7 for I-123) were performed with a dual energy window acquisition mode and two low energy general-purpose collimators. Then two planar images acquired with dual energy windows for a Tl-201 line source and an I-123 line source were obtained to measure line spread functions (LSFs) and crosstalk ratios for each image. The line source experiments showed that the LSFs for the Tl-201 imaging window from the single Tl-201 source were very similar to those for the I-123 imaging window from the single Tl-201 source, but the LSFs for the Tl-201 imaging window from the single I-123 source had broad shapes which differed from those for the I-123 imaging window from the single I-123. To obtain accurate I-123 crosstalk images in the Tl-201 imaging window from the I-123 images in the I-123 imaging window, we designed a low-pass blurring filter. In 7 clinical I-123 MIBG studies, I-123 window images processed with this filter became very similar to the Tl-201 window image from the single I-123 source. The method proposed in this study can accurately correct the crosstalk in dual isotope studies with Tl-201 and I-123 and is easily applicable to conventional gamma camera systems with any dual energy window acquisition mode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimisation of Simultaneous Tl-201/Tc-99m Dual Isotope Reconstruction with Monte-Carlo-Based Scatter Correction

Simultaneous Tl-201/Tc-99m dual isotope myocardial perfusion SPECT is seriously hampered by down-scatter from Tc-99m into the Tl-201 energy window. This paper presents and optimises the ordered-subsets-expectation-maximisation-(OS-EM-) based reconstruction algorithm, which corrects the down-scatter using an efficient Monte Carlo (MC) simulator. The algorithm starts by first reconstructing the T...

متن کامل

Completely inverse images in dual-isotope SPECT with Tl-201 and I-123 MIBG in a patient with myocarditis.

Dual-isotope myocardial SPECT in a female patient with idiopathic myocarditis showed completely inverse images in Tl-201 and I-123 MIBG SPECT. In the dual-isotope SPECT performed 13 days after her admission, Tl-201 SPECT images showed reduced accumulation in the apex and normal accumulation in the other regions, whereas the corresponding I-123 MIBG SPECT images showed normal findings in the ape...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2...

متن کامل

Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 1999