Measuring 0.1-nm motion in 1 ms in an optical microscope with differential back-focal-plane detection.
نویسندگان
چکیده
Back-focal-plane detection of micrometer-sized beads offers subnanometer resolution for single-molecule, optical trapping experiments. However, laser beam-pointing instability and mechanical drift of the microscope limit the resolution of optical-trapping experiments. By combining two infrared lasers with improved differential beam-pointing stability (< or = 0.05 microrad), we simultaneously measure and subtract the motion of the microscope stage, leading to a resolution of <0.1 nm in 1 ms and stability of 0.5 nm over 60 s. Repeated steps of 0.4 nm at 1 Hz are resolved with a signal-to-noise ratio of 25.
منابع مشابه
Stabilization of an optical microscope to 0.1 nm in three dimensions.
Mechanical drift is a long-standing problem in optical microscopy that occurs in all three dimensions. This drift increasingly limits the resolution of advanced surface-coupled, single-molecule experiments. We overcame this drift and achieved atomic-scale stabilization (0.1 nm) of an optical microscope in 3D. This was accomplished by measuring the position of a fiducial mark coupled to the micr...
متن کاملHolographic optical tweezers combined with back-focal-plane displacement detection.
A major problem with holographic optical tweezers (HOTs) is their incompatibility with laser-based position detection methods, such as back-focal-plane interferometry (BFPI). The alternatives generally used with HOTs, like high-speed video tracking, do not offer the same spatial and temporal bandwidths. This has limited the use of this technique in precise quantitative experiments. In this pape...
متن کاملSimultaneous calibration of optical tweezers spring constant and position detector response.
We demonstrate a fast and direct calibration method for systems using a single laser for optical tweezers and particle position detection. The method takes direct advantage of back-focal-plane interferometry measuring not an absolute but a differential position, i.e. the position of the trapped particle relative to the center of the optical tweezers. Therefore, a fast step-wise motion of the op...
متن کاملCalibration of optical tweezers with positional detection in the back-focal-plane
We explain and demonstrate a new method of forceand position-calibration for optical tweezers with back-focal-plane photo detection. The method combines power spectral measurements of thermal motion and the response to a sinusoidal motion of a translation stage. It consequently does not use the drag coefficient of the trapped object as an input. Thus, neither the viscosity, nor the size of the ...
متن کاملNanoscale resolution in the focal plane of an optical microscope.
Utilizing single fluorescent molecules as probes, we prove the ability of a far-field microscope to attain spatial resolution down to 16 nm in the focal plane, corresponding to about 1/50 of the employed wavelength. The optical bandwidth expansion by nearly an order of magnitude is realized by a saturated depletion through stimulated emission of the molecular fluorescent state. We demonstrate t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 29 22 شماره
صفحات -
تاریخ انتشار 2004