Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation

نویسندگان

  • Leonard W. Zimmermann
  • Ahmad Amoush
  • Douglas A. Wilkinson
چکیده

This work is a comparative study of the dosimetry calculated by Plaque Simulator, a treatment planning system for eye plaque brachytherapy, to the dosimetry calculated using Monte Carlo simulation for an Eye Physics model EP917 eye plaque. Monte Carlo (MC) simulation using MCNPX 2.7 was used to calculate the central axis dose in water for an EP917 eye plaque fully loaded with 17 IsoAid Advantage (125)I seeds. In addition, the dosimetry parameters Λ, gL(r), and F(r,θ) were calculated for the IsoAid Advantage model IAI-125 (125)I seed and benchmarked against published data. Bebig Plaque Simulator (PS) v5.74 was used to calculate the central axis dose based on the AAPM Updated Task Group 43 (TG-43U1) dose formalism. The calculated central axis dose from MC and PS was then compared. When the MC dosimetry parameters for the IsoAid Advantage (125)I seed were compared with the consensus values, Λ agreed with the consensus value to within 2.3%. However, much larger differences were found between MC calculated gL(r) and F(r,θ) and the consensus values. The differences between MC-calculated dosimetry parameters are much smaller when compared with recently published data. The differences between the calculated central axis absolute dose from MC and PS ranged from 5% to 10% for distances between 1 and 12 mm from the outer scleral surface. When the dosimetry parameters for the (125)I seed from this study were used in PS, the calculated absolute central axis dose differences were reduced by 2.3% from depths of 4 to 12 mm from the outer scleral surface. We conclude that PS adequately models the central dose profile of this plaque using its defaults for the IsoAid model IAI-125 at distances of 1 to 7 mm from the outer scleral surface. However, improved dose accuracy can be obtained by using updated dosimetry parameters for the IsoAid model IAI-125 (125)I seed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Simulation for Treatment Planning Optimization of the COMS and USC Eye Plaques Using the MCNP4C Code

Introduction: Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a ...

متن کامل

Monte Carlo simulation of two 106Ru eye plaques in a new mathematical human eye model

  BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of 106Ru, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new mod...

متن کامل

Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

متن کامل

Silastic Thickness Optimization in Uveal Melanoma Brachytherapy by Monte Carlo Method

Introduction In order to treat uveal Melanoma , first, radioactive seeds are laid on a silicone- made substance which is called Silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. The dose gradient within the tumor and healthy tissues can be varied due to changing the Silastic thickness between scler...

متن کامل

Dosimetric benefit of a new ophthalmic radiation plaque.

PURPOSE To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. METHODS AND MATERIALS One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015