Clinical Validation of a Sound Processor Upgrade in Direct Acoustic Cochlear Implant Subjects
نویسندگان
چکیده
OBJECTIVE The objectives of the investigation were to evaluate the effect of a sound processor upgrade on the speech reception threshold in noise and to collect long-term safety and efficacy data after 2½ to 5 years of device use of direct acoustic cochlear implant (DACI) recipients. STUDY DESIGN The study was designed as a mono-centric, prospective clinical trial. SETTING Tertiary referral center. PATIENTS Fifteen patients implanted with a direct acoustic cochlear implant. INTERVENTION Upgrade with a newer generation of sound processor. MAIN OUTCOME MEASURES Speech recognition test in quiet and in noise, pure tone thresholds, subject-reported outcome measures. RESULTS The speech recognition in quiet and in noise is superior after the sound processor upgrade and stable after long-term use of the direct acoustic cochlear implant. The bone conduction thresholds did not decrease significantly after long-term high level stimulation. CONCLUSIONS The new sound processor for the DACI system provides significant benefits for DACI users for speech recognition in both quiet and noise. Especially the noise program with the use of directional microphones (Zoom) allows DACI patients to have much less difficulty when having conversations in noisy environments. Furthermore, the study confirms that the benefits of the sound processor upgrade are available to the DACI recipients even after several years of experience with a legacy sound processor. Finally, our study demonstrates that the DACI system is a safe and effective long-term therapy.
منابع مشابه
Survey of Cochlear Implant User Satisfaction with the Neptune™ Waterproof Sound Processor
A multi-center self-assessment survey was conducted to evaluate patient satisfaction with the Advanced Bionics Neptune™ waterproof sound processor used with the AquaMic™ totally submersible microphone. Subjective satisfaction with the different Neptune™ wearing options, comfort, ease of use, sound quality and use of the processor in a range of active and water related situations were assessed f...
متن کاملMulticenter study with a direct acoustic cochlear implant.
OBJECTIVE To confirm the clinical efficacy and safety of a direct acoustic cochlear implant. STUDY DESIGN Prospective multicenter study. SETTING The study was performed at 3 university hospitals in Europe (Germany, The Netherlands, and Switzerland). PATIENTS Fifteen patients with severe-to-profound mixed hearing loss because of otosclerosis or previous failed stapes surgery. INTERVENTIO...
متن کاملFrequency-Limiting Effects on Speech and Environmental Sound Identification for Cochlear Implant and Normal Hearing Listeners
BACKGROUND AND OBJECTIVES It is important to understand the frequency region of cues used, and not used, by cochlear implant (CI) recipients. Speech and environmental sound recognition by individuals with CI and normal-hearing (NH) was measured. Gradients were also computed to evaluate the pattern of change in identification performance with respect to the low-pass filtering or high-pass filter...
متن کاملDeveloping a Flexible SPEAR3-Based Psychophysical Research Platform for Testing Cochlear Implant Users
An experimental psychophysical interface has been developed using Hearworks Pty Ltd’s SPEAR3 research sound processor, which is compatible with Cochlear Corporation’s Nucleus CI22 and CI24 implants. Modifications to the assembly code program file that resides in the SPEAR3 allow the parameters of a given stimulus to be updated on a trial-by-trial basis due to the responses given by a cochlear i...
متن کاملEvaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant
Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...
متن کامل