Comparison of Subjective Refraction under Binocular and Monocular Conditions in Myopic Subjects

نویسندگان

  • Hidenaga Kobashi
  • Kazutaka Kamiya
  • Tomoya Handa
  • Wakako Ando
  • Takushi Kawamorita
  • Akihito Igarashi
  • Kimiya Shimizu
چکیده

To compare subjective refraction under binocular and monocular conditions, and to investigate the clinical factors affecting the difference in spherical refraction between the two conditions. We examined thirty eyes of 30 healthy subjects. Binocular and monocular refraction without cycloplegia was measured through circular polarizing lenses in both eyes, using the Landolt-C chart of the 3D visual function trainer-ORTe. Stepwise multiple regression analysis was used to assess the relations among several pairs of variables and the difference in spherical refraction in binocular and monocular conditions. Subjective spherical refraction in the monocular condition was significantly more myopic than that in the binocular condition (p < 0.001), whereas no significant differences were seen in subjective cylindrical refraction (p = 0.99). The explanatory variable relevant to the difference in spherical refraction between binocular and monocular conditions was the binocular spherical refraction (p = 0.032, partial regression coefficient B = 0.029) (adjusted R(2) = 0.230). No significant correlation was seen with other clinical factors. Subjective spherical refraction in the monocular condition was significantly more myopic than that in the binocular condition. Eyes with higher degrees of myopia are more predisposed to show the large difference in spherical refraction between these two conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peep Into Visual Acuity Chart Through an Opening: A New Concept of Binocular Open-view Visual Acuity Test.

To the Editor: For some time we have used a clinical visual acuity test (subjective refraction) only for monocular testing. However, we believe that visual acuity measurements need to be performed under binocular open-view conditions as close to natural viewing conditions as possible. Subjective refractions without cycloplegia were examined with the Occlupad (Japan Focus Co., Ltd., Tokyo, Japan...

متن کامل

Correlation between Retinoscopy and Monocular and Binocular Subjective Refraction

Purpose: The aim of the study was to investigate if static retinoscopy has a higher correlation with monocular than binocular subjective refraction, and also to see if there is any difference between these results and Mohindra retinoscopy. Methods: Retinoscopy and subjective refraction was performed on 32 adult subjects and the results from 29 of these were analysed. Results: The statistical an...

متن کامل

Night myopia is reduced in binocular vision.

Night myopia, which is a shift in refraction with light level, has been widely studied but still lacks a complete understanding. We used a new infrared open-view binocular Hartmann-Shack wave front sensor to quantify night myopia under monocular and natural binocular viewing conditions. Both eyes' accommodative response, aberrations, pupil diameter, and convergence were simultaneously measured ...

متن کامل

A comparison of autorefraction and subjective refraction with and without cycloplegia in primary school children.

PURPOSE To evaluate the accuracy of autorefraction using three autorefractors comparing to subjective refraction in diagnosing refractive error in children. DESIGN A cross-sectional study. METHODS setting: Community based study. study population: 117 children sampled from primary schools. procedures: All subjects underwent autorefraction using three auto refractors and subjective refraction...

متن کامل

تاثیر هم افزایی دوچشمی بر مولفه های موج پتانسیل برانگیخته بینایی

  Background : To determine the effect of binocular summation on the time domain transient VEP wave's components.   Methods : The monocular and binocular transient visual evoked potentials of 21 normally vision volunteers 18 to 24 years (mean ± SD, 20.7 ± 1.9) during a reversing checkerboard stimulus with spatiotemporal frequency of 2.18-4 cpd-Hz were recorded. The amplitude and latency of N75,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015