A Novel Approach for Conducting Room-scale Vaporous Hydrogen Peroxide Decontamination of Virulent Bacillus anthracis Spores
نویسندگان
چکیده
Studies have been conducted to determine the efficacy of various decontamination technologies against virulent B. anthracis and surrogate spores within small, bench-scale chambers. This study assessed an approach for evaluating room-scale (~2,700 ft3) decontamination efficacy of vaporous hydrogen peroxide fumigation against B. anthracis Ames and B. subtilis spores deposited onto porous and non-porous indoor surface materials. Approximately 1x108 colony-forming units (CFU) of B. anthracis and B. subtilis spores were dried onto galvanized metal and ceiling tile coupons and then exposed to vaporous hydrogen peroxide. The materials contaminated with B. anthracis spores were placed inside a Class III biosafety cabinet (BSC III) that circulated vaporous hydrogen peroxide from within the decontaminated room, into and out of the BSC III. Identical materials inoculated in the same manner and at the same density with B. subtilis were placed both inside and outside of the BSC III to compare decontamination efficacy. Three fumigations were conducted using two sets of cycle parameters. The first set of cycle parameters for vaporous hydrogen peroxide exposure (10 minutes of conditioning at 12 g/min; 75 minutes of decontamination at 11 g/min) yielded log reductions in viable B. anthracis and B. subtilis spores ranging from 6.1 to 7.0 on all materials, while only 76% of the commercial biological indicators (1x106 CFU) evaluated in parallel were completely inactivated. The second set of cycle parameters (12 minutes of conditioning at 12 g/min; 104 minutes of decontamination at 8 g/min) yielded log reductions in viable B. anthracis and B. subtilis spores ranging from 6.7 to 7.4 on all materials and complete inactivation of biological indicators. These results demonstrate this method as a viable approach to assess room-scale fumigant decontamination efficacy against B. anthracis Ames spores.
منابع مشابه
Inactivation of Francisella tularensis Schu S4 in a Biological Safety Cabinet Using Hydrogen Peroxide Fumigation
This study evaluated the inactivation of Francisella tularensis Schu S4 on various materials (acrylic, glass, polyamide, polyethylene, polypropylene, silicone rubber, and stainless steel) using hydrogen peroxide fumigation of a Class III Biological Safety Cabinet (BSC III). A suspension of F. tularensis Schu S4 (7 x 10 CFU) was dried on seven different types of test surfaces and exposed to vapo...
متن کاملDetermination of anthrax foci through isolation of Bacillus anthracis form soil samples of different regions of Iran
To isolate and detect anthrax spores form soil in different regions of Iran in order to find the anthrax foci‚ a total of 668 environmental specimens were collected during 2003-2004. Bacterial endospores were extracted from soil specimens via flotation in distilled water, incubation at room temperature, filtration, heat shock and culture on blood agar and selective PLET media. Bacillus anthraci...
متن کاملFormaldehyde Solution Effectively Inactivates Spores of Bacillus anthracis on the Scottish Island of Gruinard.
Gruinard Island was heavily contaminated with the spores of virulent Bacillus anthracis during biological weapons trials in World War II. However, an extensive survey in 1979 showed that most of the island was not contaminated. In the early 1980s, a more intensive survey revealed that the contamination was largely confined to the top 8 cm of the soil in a 2.6-ha area of the 211-ha island. Small...
متن کاملStability and potency studies of anthrax vaccine (Bacillus anthracis 34F2 Sterne strain) in Iran
For evaluation the stability and potency of anthrax vaccine prepared in Razi Vaccine and Serum Research Institute in Iran, samples of different batches of vaccine were kept at 4-8 °C (refrigerator), 20-25 °C (room temperature) and 37 °C (incubator).The viable spores/ml of vaccines were determined using plate–counting method before and after holding at different temperatures monthly. Vaccine p...
متن کاملQuantitative method to determine sporicidal decontamination of building surfaces by gaseous fumigants, and issues related to laboratory-scale studies.
Chlorine dioxide gas and vaporous hydrogen peroxide sterilant have been used in the cleanup of building interiors contaminated with spores of Bacillus anthracis. A systematic study, in collaboration with the U.S. Environmental Protection Agency, was jointly undertaken by the U.S. Army-Edgewood Chemical Biological Center to determine the sporicidal efficacies of these two fumigants on six buildi...
متن کامل