Transthoracic Doppler echocardiographic measurement of left atrial appendage blood flow velocity: comparison with transoesophageal measurement.
نویسندگان
چکیده
AIM We validated transthoracic echocardiographic measurements of left atrial appendage flow velocity by comparing them with transoesophageal echocardiographic measurements. METHODS AND RESULTS Eighty-four consecutive patients (mean age, 64.6 years) with various cardiac diseases, who underwent both transthoracic echocardiography and transoesophageal echocardiography were studied. Thirty-two patients were in sinus rhythm, and the remaining 52 patients were in atrial fibrillation. On transthoracic echocardiography, the transducer was placed somewhat superior and outside from the position viewing the conventional parasternal short-axis image of the aortic valve, so that the angle between left atrial appendage midline and Doppler beam could be narrowed. The left atrial appendage flow velocity pattern was recorded by pulsed Doppler mode with a sampling volume placed at the left atrial appendage orifice on both transthoracic echocardiography and transoesophageal echocardiography. In both approaches, the peak emptying velocity (LAA-E) and the peak filling velocity (LAA-F) of the left atrial appendage were measured. In sinus rhythm, the LAA-E was detectable in 25 of the 32 patients (78.1%) and the LAA-F in 20 of the 32 patients (62.5%). Both LAA-E and LAA-F were detectable in 46 of the 52 patients (88.5%) in atrial fibrillation. Good correlations of LAA-E and LAA-F were observed between transthoracic echocardiography and transoesophageal echocardiography measurements in sinus rhythm (r=0.94, r=0.95, respectively; both, P<0.0001) and in atrial fibrillation (r=0.89, r=0.95, respectively; both, P<0.0001). CONCLUSIONS The left atrial appendage flow velocities could be sufficiently recorded and assessed by transthoracic echocardiography in 84 Japanese unselected consecutive patients with sinus rhythm or atrial fibrillation.
منابع مشابه
Imaging of thrombi and assessment of left atrial appendage function: a prospective study comparing transthoracic and transoesophageal echocardiography.
OBJECTIVE To compare the value of current transthoracic echocardiographic systems and transoesophageal echocardiography for assessing left atrial appendage function and imaging thrombi. DESIGN Single blind prospective study. Patients were first investigated by transthoracic echocardiography and thereafter by a second investigator using transoesophageal echocardiography. The feasibility of ima...
متن کاملSpeckle-tracking strain of the left atrium: a transoesophageal echocardiographic validation study.
AIMS The aims of this study were (1) to evaluate the relationship between novel two-dimensional transthoracic indices of left atrial (LA) mechanical function (speckle-tracking- and tissue Doppler-derived parameters), conventional indices (A-wave peak velocity and velocity-time integral, and A' velocity), and transoesophageal echocardiographic parameters (LA appendage emptying velocity and spont...
متن کاملClinical value of left atrial appendage flow velocity for predicting of cardioversion success in patients with non-valvular atrial fibrillation.
BACKGROUND Echocardiographic parameters for predicting cardioversion outcome in patients with non-valvular atrial fibrillation are not accurately defined. OBJECTIVE To evaluate the role of left atrial appendage flow velocity detected by transoesophageal echocardiography for prediction of cardioversion outcome in patients with non-valvular atrial fibrillation enrolled in a prospective. multice...
متن کاملCARDIOVASCULAR MEDICINE Atrial fibrillation: relation between clinical risk factors and transoesophageal echocardiographic risk factors for thromboembolism
Objective: To correlate clinical risk factors for thromboembolism with transoesophageal echocardiography (TOE) markers of a thrombogenic milieu. Design: Clinical risk factors for thromboembolism and TOE markers of a thrombogenic milieu were assessed in consecutive patients with non-rheumatic atrial fibrillation. The following TOE parameters were assessed: presence of spontaneous echo contrast, ...
متن کاملEstimation of left atrial blood stasis using diastolic late mitral annular velocity.
AIMS Diastolic late mitral annular velocity (a') measured by transthoracic echocardiography (TTE) is reported to represent left atrial (LA) pump function and the severity of LA remodelling. The purpose of this study is to investigate the association between a' and LA blood stasis in patients with non-valvular paroxysmal atrial fibrillation. METHODS AND RESULTS We enrolled 138 consecutive pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology
دوره 4 3 شماره
صفحات -
تاریخ انتشار 2003