Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors.

نویسندگان

  • J B Fink
  • R Dhand
  • J Grychowski
  • P J Fahey
  • M J Tobin
چکیده

We attempted to resolve the discrepancies in reported data on aerosol deposition from a chlorofluorocarbon (CFC)-propelled metered-dose inhaler (MDI) during mechanical ventilation, obtained by in vivo and in vitro methodologies. Albuterol delivery to the lower respiratory tract was decreased in a humidified versus a dry circuit (16.2 versus 30.4%, respectively; p < 0.01). In 10 mechanically ventilated patients, 4.8% of the nominal dose was exhaled. When the exhaled aerosol was subtracted from the in vitro delivery of 16.2% achieved in a humidified ventilator circuit, the resulting value (16.2 - 4.8 = 11.4%) was similar to in vivo estimates of aerosol deposition. Having reconciled in vitro with in vivo findings, we then evaluated factors influencing aerosol delivery. A lower inspiratory flow rate (40 versus 80 L/min; p < 0.001), a longer duty cycle (0.50 versus 0.25; p < 0.04), and a shorter interval between successive MDI actuations (15 versus 60 s; p < 0.02) increased aerosol delivery, whereas use of a hydrofluoroalkane (HFA)-propelled MDI decreased aerosol delivery compared with the CFC-propelled MDI. A MDI and actuator combination other than that designed by the manufacturer altered aerosol particle size and decreased drug delivery. In conclusion, aerosol delivery in an in vitro model accurately reflects in vivo delivery, providing a means for investigating methods to improve the efficiency of aerosol therapy during mechanical ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Basic techniques for aerosol delivery during mechanical ventilation.

Among the devices employed for aerosol generation (metered-dose inhalers, nebulizers, and dry powder inhalers) only metered-dose inhalers and nebulizers are routinely employed for aerosol delivery to mechanically ventilated patients. The ventilator circuit and artificial airway were previously thought to be major barriers to effective aerosol delivery to mechanically ventilated patients. In the...

متن کامل

Aerosol delivery during mechanical ventilation: from basic techniques to new devices.

Pressurized metered-dose inhalers (pMDIs) and nebulizers are routinely employed for aerosol delivery in mechanically ventilated patients. A significant proportion of the aerosol deposits in the ventilator circuit and artificial airway, thereby reducing the inhaled drug mass. Factors influencing aerosol delivery during mechanical ventilation differ from those in spontaneously breathing patients....

متن کامل

Inhalation therapy in patients receiving mechanical ventilation: an update.

Incremental gains in understanding the influence of various factors on aerosol delivery in concert with technological advancements over the past 2 decades have fueled an ever burgeoning literature on aerosol therapy during mechanical ventilation. In-line use of pressurized metered-dose inhalers (pMDIs) and nebulizers is influenced by a host of factors, some of which are unique to ventilator-sup...

متن کامل

High impact aerosol technology offers higher efficiency, but is not ready for prime time.

The therapeutic administration of medical aerosols has been a standard adjunct to treatment of critically ill patients since positive-pressure mechanical ventilators were introduced over 60 years ago, and most ventilators can operate a jet nebulizer in synchrony with mechanically delivered breaths. However, for the first 40 years, little was known about the efficiency of aerosol delivery during...

متن کامل

Inhalation therapy with metered-dose inhalers and dry powder inhalers in mechanically ventilated patients.

Pressurized metered-dose inhalers (pMDIs) are commonly employed for administering bronchodilator aerosols to mechanically ventilated patients. Although it is feasible to employ dry powder inhalers in ventilator circuits, the presence of humidity in the ventilator circuit could reduce their efficiency. A complex array of factors influence drug delivery from pMDIs during mechanical ventilation, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of respiratory and critical care medicine

دوره 159 1  شماره 

صفحات  -

تاریخ انتشار 1999