The NIST Detector-Based Luminous Intensity Scale

نویسندگان

  • C. L. Cromer
  • G. Eppeldauer
  • J. E. Hardis
  • T. C. Larason
  • Y. Ohno
  • A. C. Parr
چکیده

The Système International des Unités (SI) base unit for photometry, the candela, has been realized by using absolute detectors rather than absolute sources. This change in method permits luminous intensity calibrations of standard lamps to be carried out with a relative expanded uncertainty (coverage factor k = 2, and thus a 2 standard deviation estimate) of 0.46 %, almost a factor-of-two improvement. A group of eight reference photometers has been constructed with silicon photodiodes, matched with filters to mimic the spectral luminous efficiency function for photopic vision. The wide dynamic range of the photometers aid in their calibration. The components of the photometers were carefully measured and selected to reduce the sources of error and to provide baseline data for aging studies. Periodic remeasurement of the photometers indicate that a yearly recalibration is required. The design, characterization, calibration, evaluation, and application of the photometers are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Photometric Standards and Calibration Procedures at NIST

NIST has recently established a detector-based luminous intensity unit (candela, cd), which is derived from the NIST absolute cryogenic radiometer. Subsequently, the luminous flux unit (lumen, lm) and the luminance unit (cd/m2) have been established based on the detector-based candela, and now all the NIST photometric units are tied to the cryogenic radiometer. The illuminance unit is realized ...

متن کامل

1993 Intercomparison of Photometric Units Maintained at NIST (USA) and PTB (Germany)

A bilateral intercomparison of photometric units between NIST, USA and PTB, Germany has been conducted to update the knowledge of the relationship between the photometric units disseminated in each country. The luminous intensity unit (cd) and the luminous flux unit (lm) maintained at both laboratories are compared by circulating transfer standard lamps. Also, the photometric responsivity sv is...

متن کامل

The Detector-Based Candela Scale and Related Photometric Calibration Procedures at NIST

The candela, one of the SI base units, has been realized by using absolutely calibrated detectors rather than sources. A group of eight photometers was constructed using silicon photodiodes, precision apertures, and glass filters for V (λ) match. Their absolute spectral responsivities were calibrated against the NIST absolute spectral responsivity scale. The measurement chain has been significa...

متن کامل

New Photometric Calibration Programs at the National Institute of Standards and Technology

The NIST candela is maintained via standard photometers which have shown long-term stability better than 0.1% per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at NIST. A high-illuminance calibration facility has been developed. Four temperatur...

متن کامل

New photometric calibration programmes at the National Institute of Standards and Technology

The National Institute of Standards and Technology (NIST) candela is maintained via standard photometers which have shown long-term stability of better than 0.1 % per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at the NIST. A high-illuminance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 101  شماره 

صفحات  -

تاریخ انتشار 1996