Validation of sensor for postoperative positioning with intraocular gas

نویسندگان

  • Frank L Brodie
  • Kelly Y Woo
  • Ashwin Balakrishna
  • Hyuck Choo
  • Robert H Grubbs
چکیده

PURPOSE Surgical repair of retinal attachment or macular hole frequently requires intraocular gas. This necessitates specific postoperative positioning to improve outcomes and avoid complications. However, patients struggle with correct positioning. We have developed a novel sensor to detect the position of the gas bubble in the eye and provide feedback to patients in real time. In this paper, we determine the specificity and sensitivity of our sensor in vitro using a model eye. METHODS We assessed the reliability of our sensor to detect when a gas bubble has deviated off a model retinal break in a model eye. Various bubble sizes representing the intraocular kinetics of sulfur hexafluoride gas and varying degrees of deviation from the correct position were tested using the sensor attached to a mannequin head with a model eye. RESULTS We recorded 36 data points. The sensor acted appropriately in 33 (91.7%) of them. The sensor triggered the alarm every time the bubble deviated off the break (n=15, sensitivity =100%). However, it triggered the alarm (falsely) 3/21 times when the bubble was correctly positioned over the retinal break (specificity =86%). CONCLUSION Our device shows excellent sensitivity (100%) and specificity (86%) in detecting whether intraocular gas is tamponading a retinal break in a model eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel positioning sensor with real-time feedback for improved postoperative positioning: pilot study in control subjects

INTRODUCTION Repair of retinal detachment frequently requires use of intraocular gas. Patients are instructed to position themselves postoperatively to appose the intraocular bubble to the retinal break(s). We developed a novel wearable wireless positioning sensor, which provides real-time audiovisual feedback on the accuracy of positioning. METHODS Eight healthy volunteers wore the wireless ...

متن کامل

3D Path Planning Algorithm for Mobile Anchor-Assisted Positioning in Wireless Sensor Networks

Positioning service is one of Wireless Sensor Networks’ (WSNs) fundamental services. The accurate position of the sensor nodes plays a vital role in many applications of WSNs. In this paper, a 3D positioning algorithm is being proposed, using mobile anchor node to assist sensor nodes in order to estimate their positions in a 3D geospatial environment. However, mobile anchor node’s 3D path optim...

متن کامل

Microscopic analysis of an opacified OFT CRYL® hydrophilic acrylic intraocular lens.

A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and ...

متن کامل

AIR VERSUS GAS TAMPONADE IN RHEGMATOGENOUS RETINAL DETACHMENT WITH INFERIOR BREAKS AFTER 23-GAUGE PARS PLANA VITRECTOMY: A Prospective, Randomized Comparative Interventional Study.

PURPOSE To compare the efficacy of air and octafluoropropane (C3F8) in treating rhegmatogenous retinal detachments with inferior breaks after 23-gauge pars plana vitrectomy. METHODS A prospective, randomized comparative interventional study. Sixty-four patients with rhegmatogenous retinal detachment with inferior breaks underwent pars plana vitrectomy with air (32 eyes) or gas (32 eyes) tampo...

متن کامل

[Macular hole surgery without postoperatory <<face>> down positioning. Pilot study].

PURPOSE To evaluate the visual and anatomical outcomes of macular hole surgery using phacoemulsification, vitrectomy and intraocular gas tamponade without the use of postoperative face down positioning. METHODS Phacoemulsification with an intraocular lens implant, followed by vitrectomy with internal limiting membrane peeling and perfluoropropane (C3F8), was performed in patients with stage 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016