Site evaluation of harmonics distortions from modern wind turbines based on voltage source and harmonic impedances models
نویسندگان
چکیده
The modern wind turbines (WT), equipped with power converters (full or partial power converters) connected to the grid, have increased rapidly in recent years. Harmonic assessment of the power quality is a necessary study for interconnection of future wind farm to the grid. Normally, the power quality assessment in wind farm is done considering the power converter as an ideal harmonic current source, then, the injected harmonic currents are considered constant in any grid. This approach is not always valid since it neglects any grid harmonic impedance impact as well as the converter reaction to background harmonic voltages. In this study it has been modelled the Alstom Haliade 150 6MW wind turbine converter as a harmonic voltage source, including its filter and transformer harmonic model; with the theoretical harmonic impedance model and the background harmonic voltages of Le Carnet Wind farm (France) . The predicted voltage and current harmonics have been compared with real data measurement. The accuracy of this evaluation is much closer to reality than considering converters as ideal current sources as usual.
منابع مشابه
Wind Power Harmonic Emission versus Active-Power Production
Modern wind turbines are commonly equipped with power electronics. The application of either a partial scale frequency converter or a full scale power converter will result in harmonic emission which is distinct from conventional harmonic sources: even harmonics and interharmonics appear with similar magnitudes as odd harmonics. Harmonic and interharmonic measurements on a few individual wind t...
متن کاملA New Method to Study Aggregation Effect of Harmonic Current Emissions in a Wind Farm Based on Type-III Wind Turbine Average Modeling
Assessment of complex harmonic current contribution of each wind turbines at connection point of a wind farm to the grid (primary emission) is presented in this paper. Moreover, contribution of grid background harmonic voltage distortion on harmonic current distortion (secondary emission) of each turbine is also evaluated. Both assessments are represented based on primary and secondary transfer...
متن کاملDesign and Implementation of a Kalman Filter-Based Time-Varying Harmonics Analyzer
Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...
متن کاملA Fast and Efficient On-Line Harmonics Elimination Pulse Width Modulation for Voltage Source Inverter Using Polynomials Curve Fittings
The paper proposes an algorithm to calculate the switching angles using harmonic elimination PWM (HEPWM) scheme for voltage source inverter. The algorithm is based on curve fittings of a certain polynomials functions. The resulting equations require only the addition and multiplication processes; therefore, it can be implemented efficiently on a microprocessor. An extensive angle error analysis...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کامل