Increasing computer-aided detection specificity by projection features for CT colonography.

نویسندگان

  • Hongbin Zhu
  • Zhengrong Liang
  • Perry J Pickhardt
  • Matthew A Barish
  • Jiangsheng You
  • Yi Fan
  • Hongbing Lu
  • Erica J Posniak
  • Robert J Richards
  • Harris L Cohen
چکیده

PURPOSE A large number of false positives (FPs) generated by computer-aided detection (CAD) schemes is likely to distract radiologists' attention and decrease their interpretation efficiency. This study aims to develop projection-based features which characterize true and false positives to increase the specificity while maintaining high sensitivity in detecting colonic polyps. METHODS In this study, two-dimensional projection images are obtained from each initial polyp candidate or volume of interest, and features are extracted from both the gray and color projection images to differentiate FPs from true positives. These projection features were tested to exclude different types of FPs, such as haustral folds, rectal tubes, and residue stool using a database of 325 patient studies (from two different institutions), which includes 556 scans at supine and/or prone positions with 347 polyps and masses sized from 5 to 60 mm. For comparison, several well-established features were used to generate a baseline reference. The experimental evaluation was conducted for large polyps (> or = 10 mm) and medium-sized polyps (5-9 mm) separately. RESULTS For large polyps, the additional usage of the projection features reduces the FP rate from 5.31 to 1.92 per scan at the comparable by-polyp sensitivity level of 93.1%. For medium-sized polyps, the FP rate is reduced from 8.89 to 5.23 at the sensitivity level of 80.6%. The percentages of FP reduction are 63.9% and 41.2% for the large and medium-sized polyps, respectively, without sacrificing detection sensitivity. CONCLUSIONS The results have demonstrated that the new projection features can effectively reduce the FPs and increase the detection specificity without sacrificing the sensitivity. CAD of colonic polyps is supposed to help radiologists to improve their performance in interpreting computed tomographic colonography images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Projection-based features for reducing false positives in computer-aided detection of colonic polyps in CT colonography [7624-10]

A large number of false positives (FPs) generated by computer-aided detection schemes is likely to distract radiologists’ attention and decreases their interpretation efficiency. Therefore, it is desirable to reduce FPs as many as possible to increase the detection specificity while maintaining the high detection sensitivity. In this paper, several features are extracted from the projected imag...

متن کامل

Using Optical Flow Fields for Polyp Detection in Virtual Colonoscopy

Since the introduction of Computed Tomographic Colonography (CTC), research has mainly focused on visualization and navigation techniques. Recently, efforts have shifted towards computer aided detection (CAD) of polyps. We propose a new approach to CAD in CT images that attempts to model the way a radiologist recognizes a polyp using optical flow fields (OFF). Features extracted from OFFs are u...

متن کامل

Computer-aided diagnosis scheme for detection of polyps at CT colonography.

Colon cancer is one of the leading causes of cancer deaths in the United States. However, most colon cancers can be prevented if precursor colonic polyps are detected and removed. An advanced computer-aided diagnosis (CAD) scheme was developed for the automated detection of polyps at computed tomographic (CT) colonography. A region encompassing the colonic wall is extracted from an isotropic vo...

متن کامل

Current concepts and future directions in computer-aided diagnosis for CT colonography

This review summarizes recent progress in computer-aided detection for CT colonography.

متن کامل

Recent advances in automated lesion detection for CT colonography by second order curvature flow

Over the past few years, techniques for CT colonography evolved rapidly, stimulated by encouraging performance data. Computer aided detection (CAD) methods were developed that enhance the efficiency of reading the data. Our objective in this paper is to review some recent advances on this topic, by others as well by ourselves.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2010