Evaluation of the BOD POD for estimating percent body fat in collegiate track and field female athletes: a comparison of four methods.

نویسندگان

  • Keren M Bentzur
  • Len Kravitz
  • Donna W Lockner
چکیده

This investigation examined the accuracy of the BOD POD on a group of Division I collegiate track and field female athletes (N = 30). Hydrostatic weighing (HW) was used as the gold standard method. Body density (Db) values obtained from the BOD POD (Db BP) were compared with those determined by HW (Db HW). Both Db values were converted to percent body fat (%BF) using the Siri equation for comparison. Percent body fat values obtained from the BOD POD (BF BP) were also compared with those obtained from dual-energy X-ray absorptiometry (DXA, BF DXA) and skinfold (SF, BF SF). The validity of the BOD POD was assessed using repeated-measures analysis of variance (ANOVA), and the relationship between the methods was examined through Pearson correlation. Average Db BP was 0.00890 g x cm(-3) lower (p < 0.05) than Db HW, resulting in a significant overestimation of %BF (p < 0.05) by the BOD POD. Values for BFDXA and BFBP also differed significantly (p < 0.05). On the other hand, BFSF and BF BP were not significantly different. The correlation between percent body fat values obtained from HW (BFHW) and BF BP was good (r = 0.88, SEE = 2.30) as well as between BF SF and BF BP (r = 0.85, SEE = 2.05). Conversely, the correlation between BFDXA and BF BP was poor (r = 0.25, SEE = 5.73). The strong correlation between BF BP and BF HW presented here suggests that the BOD POD has the potential to be used as a body composition analysis tool for female athletes. The advantages of the BOD POD over HW encourage further investigation of this instrument. However, the fact that the BOD POD and SF results did not differ significantly might suggest that the SF could be used in its place until a better rate of accuracy for this instrument is established.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity and Reliability of A-Mode Ultrasound for Body Composition Assessment of NCAA Division I Athletes.

This study evaluated the validity and reliability of the BodyMetrix™ BX2000 A-mode ultrasound for estimating percent body fat (%BF) in athletes by comparing it to skinfolds and the BOD POD. Forty-five (22 males, 23 females) National Collegiate Athletic Association (NCAA) Division-I athletes volunteered for this study. Subjects were measured once in the BOD POD then twice by two technicians for ...

متن کامل

Predicted versus measured thoracic gas volumes of collegiate athletes made by the BOD POD air displacement plethysmography system.

Measured (TGVm) and predicted (TGVp) thoracic gas volumes from the BOD POD were compared in 33 lean, university athletes. On average, TGVp (3.529 L) was not significantly different (p = 0.343) from TGVm (3.628 L); however, there was a bias (r = -0.703, p < 0.001). The difference in the percentage of body fat (BF) was within ±2% BF for 76% of the sample, but athletes at the extremes of height sh...

متن کامل

Body Fat Measurements in Singaporean Adults Using Four Methods

Few studies have been conducted to measure body composition in Asian populations. In this study, we determined the percent body fat (PBF) by using dual-energy X-ray absorptiometry (DEXA), air-displacement plethysmography (ADP or BOD POD), bioelectrical impedance analysis (BIA) and skinfold (SKF) in 445 healthy Singaporean adults. We observed that the BOD POD, BIA and SKF estimates of PBF were h...

متن کامل

Evaluation of air displacement for assessing body composition of collegiate wrestlers.

PURPOSE To evaluate the accuracy of air displacement plethysmography (ADP) by using the BOD POD in comparison with hydrostatic weighing (HW) in a collegiate wrestling population in hydrated and acutely dehydrated states. METHODS Body composition was determined by ADP, HW, and three-site skinfolds (SK) in 66 NCAA Division I collegiate wrestlers before and after acute dehydration (2.6% reductio...

متن کامل

Air Displacement Plethysmography versus Dual-Energy X-Ray Absorptiometry in Underweight, Normal-Weight, and Overweight/Obese Individuals

BACKGROUND Accurately estimating fat percentage is important for assessing health and determining treatment course. Methods of estimating body composition such as hydrostatic weighing or dual-energy x-ray absorptiometry (DXA), however, can be expensive, require extensive operator training, and, in the case of hydrostatic weighing, be highly burdensome for patients. Our objective was to evaluate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of strength and conditioning research

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2008