An operative gamma camera for sentinel lymph node procedure in case of breast cancer

نویسندگان

  • S. Salvador
  • V. Bekaert
  • C. Mathelin
  • D. Huss
چکیده

Large field of view gamma cameras are widely used to perform lymphoscintigraphy in the sentinel lymph nodes (SLN) procedure in case of breast cancer. However, they are not specified for this application and their sizes do not enable their use in the operative room to control the excision of the all SLN. We present the results obtained with a prototype of a new mini gamma camera developed especially for the operative lymphoscintigraphy of the axillary area in case of breast cancer. This prototype is composed of 10 mm thick parallel lead collimator, a 2 mm thick GSO:Ce inorganic scintillating crystal from Hitachi and a Hamamatsu H8500 flat panel multianode (64 channels) photomultiplier tube (MAPMT) equipped with a dedicated electronics. Its actual field of view is 50 × 50 mm2. The gamma interaction position in the GSO scintillating plate is obtained by calculating the center of gravity of the fired MAPMT channels. The measurements performed with this prototype demonstrate the usefulness of this mini gamma camera for the pre, per and post-operative identification of SLN’s and how its complementary role with an intraoperative handheld gamma probe enables to improve the efficiency of this practice. A 100 × 100 mm2 field of view camera designated to cover the entire axillary area is under investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of sentinel lymph node biopsy in breast cancer using an operative gamma camera

BACKGROUND Sentinel lymph node (SLN) procedure is now a widely accepted method of LN staging in selected invasive breast cancers (unifocal, size </= 2 cm, clinically N0, without previous treatment). Complete axillary clearance is no longer needed if the SLN is negative. However, the oncological safety of this procedure remains to be addressed in randomized clinical trials. One main pitfall is t...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

The need for skin pen marking for sentinel lymph node biopsy: A comparative study

  Introduction: There is a consensus in the literature that sentinel lymph node biopsy is the standard procedure for axillary staging in early stage (I and II) breast cancer patients. Usually during lymphoscintigraphy, the location of the sentinel lymph node is marked on the skin by an indelible ink. In this study we evaluated this issue in our patients. Methods: 40 ...

متن کامل

Monte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping

Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...

متن کامل

Radiotracer re-injection in case of sentinel node non-visualization in a breast cancer patient

We reported a 35 year old breast cancer patient who was referred to our nuclear medicine department for sentinel node mapping. She was planned to undergo mastectomy and lymphatic mapping. A dose of Tc-99m Phytate was injection in the peri-areolar region in an intra-dermal fashion. Two hours post-injection no sentinel node was visible in the axilla. Due to a high liver uptake, inadvertent intra-...

متن کامل