[Reproducibility of the QFT-G-IT assay in the contact examination in which a high positive rate was shown independent of contact time].
نویسندگان
چکیده
OBJECTIVE A contact examination conducted using the QuantiFERON-TB GOLD In-Tube (QFT-G-IT) assay shows a high positive rate independent of the closeness of contact. Among individuals with a short contact time of only 1.1 +/- 1.3 h with the index tuberculosis (TB) case, the QFT-G-IT assay positive rate was 13.9%, which was considered extraordinarily high (for reference, the proportion of previously infected individuals in the Japanese general population with the same age has been estimated to be approximately 7.3%). We retested the QFT-G-IT-positive contacts to examine the reproducibility of the QFT-G-IT assay and to confirm the reliability of the test results. METHOD Of the 216 participants who underwent the first examination, 33 who tested positive (23 close contacts and 10 casual contacts) were retested by an experienced technician at the same laboratory; care was taken to minimize possible causes of variations (method of shaking tubes, temperature, vibration during transportation of the specimens, etc.). In addition, the participants were tested using other interferon (IFN)-gamma release assays (IGRAs), namely, QuantiFERON-TB GOLD (QFT-G) and T-SPOT, in order to confirm the reliability of the QFT-G-IT assay. RESULT Among the 33 retested participants, only 7 (4 close contacts and 3 casual contacts) tested positive, and the remaining 26 participants (19 close contacts and 7 casual contacts) had discordant results. Out of the 11 participants (33.3%) in whom IFN-gamma levels varied between 0.35 and 0.50 IU/ml (just above the diagnostic cut-off) in the initial test, 10 (90.9%) tested negative, with IFN- gamma levels being less than 0.35 IU/ml in the retest. The results of the different IGRAs showed moderate to high agreement, with kappa values of 0.406 between QFT-G-IT and QFT-G and 0.604 between QFT-G-IT and T-SPOT. CONCLUSION The findings of this study showed that the QFT-G-IT assay was not reproducible and robust. Judging from the agreement between the different IGRAs, it seems that the results of the retest conducted using the QFT-G-IT assay had a higher reliability than those of the initial test. In the QFT-G-IT retest, reversion from positive to negative occurred mostly in the case of participants with initial measurements just above the diagnostic cut-off. Therefore, attention must be given not only to the dichotomous results (positive or negative) but also to the exact level of IFN-gamma production. The results of the QFT-G-IT assay may also be affected by various environmental factors. If the QFT-G-IT assay yields a high positive rate disproportionate to the closeness of contact, the result should be carefully interpreted, taking into account the unreliability of the QFT-G-IT assay as a possible cause of discordance. Further studies under various settings are needed to establish the reliability of IGRAs.
منابع مشابه
QuantiFERON-TB Gold and Tuberculin Skin Test for the Diagnosis of Latent Tuberculosis Infection in Children
Background: Appropriate diagnosis and treatment of latent tuberculosis infection (LTBI) play the most important role in the control of tuberculosis. This study aimed to determine the prevalence of LTBI among healthy tuberculosis unexposed children vaccinated with BCG using the tuberculin skin test (TST) and QuantiFERON TB Gold In-Tube (QFT-GIT) and comparing the agreement between the two tests....
متن کاملAdsorption and Optimization Removal of Co(tsPc)-4 from aqueous solution using Nanoalumina
In the present study, adsorption of Co(tsPc)-4 using γ-Alumina was investigated. γ-Alumina was prepared by gel combustion method. The XRD pattern revealed that the synthesized γ-Alumina is amorphous and SEM image showed its nanosize scale while BET surface area about 501 m2/g and pore size of 7 nm implies highly porous surface which is a characteristic property of a high-quality adsorbent. In t...
متن کاملDye Adsorption on the Blends of Saffron Petals Powder with Activated Carbon: Response Surface Methodology
One of the famous dyes is methylene blue (MB) which is a symbol of hazardous dyes. In this research, methylene blue was adsorbed using the blends of saffron petals with activated carbon. Five independent variables involving pH (2-13), contact time (5-270 min), saffron petals powder dosage (0.1-10 g/l), initial concentration of methylene blue solution (20-300 ppm) and activated carbon dosage (0....
متن کاملTuberculosis contact investigation with a new, specific blood test in a low-incidence population containing a high proportion of BCG-vaccinated persons
BACKGROUND BCG-vaccination can confound tuberculin skin test (TST) reactions in the diagnosis of latent tuberculosis infection. METHODS We compared the TST with a Mycobacterium tuberculosis specific whole blood interferon-gamma assay (QuantiFERON-TB-Gold In Tube; QFT-G) during ongoing investigations among close contacts of sputum smear positive source cases in Hamburg, Germany. RESULTS Duri...
متن کاملApplication of Multi-Walled Carbon Nanotubes in the Removal of Reactive Red 120 from Aqueous Solutions
Background and purpose: Textile effluents are very difficult to treat satisfactorily due to high variations in their compositions. Strong color is one of the main characteristics of textile effluent and, if not eliminated, it can cause serious problems to the environment. In the present study, multi-walled carbon nanotubes (MWCNTs) were used as an adsorbent for the removal of Reactive Red-120 (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Kekkaku : [Tuberculosis]
دوره 87 4 شماره
صفحات -
تاریخ انتشار 2012