Extremely low-frame-rate digital fluoroscopy in catheter ablation of atrial fibrillation

نویسندگان

  • Ji Hyun Lee
  • Jun Kim
  • Minsu Kim
  • Jongmin Hwang
  • You Mi Hwang
  • Joon-Won Kang
  • Gi-Byoung Nam
  • Kee-Joon Choi
  • You-Ho Kim
چکیده

Despite the technological advance in 3-dimensional (3D) mapping, radiation exposure during catheter ablation of atrial fibrillation (AF) continues to be a major concern in both patients and physicians. Previous studies reported substantial radiation exposure (7369-8690 cGy cm) during AF catheter ablation with fluoroscopic settings of 7.5 frames per second (FPS) under 3D mapping system guidance. We evaluated the efficacy and safety of a low-frame-rate fluoroscopy protocol for catheter ablation for AF.Retrospective analysis of data on 133 patients who underwent AF catheter ablation with 3-D electro-anatomic mapping at our institute from January 2014 to May 2015 was performed. Since January 2014, fluoroscopy frame rate of 4-FPS was implemented at our institute, which was further decreased to 2-FPS in September 2014. We compared the radiation exposure quantified as dose area product (DAP) and effective dose (ED) between the 4-FPS (n = 57) and 2-FPS (n = 76) groups.The 4-FPS group showed higher median DAP (599.9 cGy cm; interquartile range [IR], 371.4-1337.5 cGy cm vs. 392.0 cGy cm; IR, 289.7-591.4 cGy cm; P < .01), longer median fluoroscopic time (24.4 min; IR, 17.5-34.9 min vs. 15.1 min; IR, 10.7-20.1 min; P < .01), and higher median ED (1.1 mSv; IR, 0.7-2.5 mSv vs. 0.7 mSv; IR, 0.6-1.1 mSv; P < .01) compared with the 2-FPS group. No major procedure-related complications such as cardiac tamponade were observed in either group. Over follow-up durations of 331 ± 197 days, atrial tachyarrhythmia recurred in 20 patients (35.1%) in the 4-FPS group and in 27 patients (35.5%) in the 2-FPS group (P = .96). Kaplan-Meier survival analysis revealed no significant different between the 2 groups (log rank, P = .25).In conclusion, both the 4-FPS and 2-FPS settings were feasible and emitted a relatively low level of radiation compared with that historically reported for DAP in a conventional fluoroscopy setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation exposure during catheter ablation of atrial fibrillation.

BACKGROUND The purpose of this study was to determine the radiation exposure during catheter ablation of atrial fibrillation (AF) using the pulmonary vein (PV) approach. METHODS AND RESULTS The study included 15 patients with AF and 5 patients each with atrial flutter and atrioventricular nodal reentrant tachycardia (AVNRT) who underwent fluoroscopically guided procedures on a biplane x-ray s...

متن کامل

Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping.

BACKGROUND Catheter ablation of atrial fibrillation is currently guided by x-ray fluoroscopy. The associated radiation risk to patients and medical staff may be significant. We report an atrial fibrillation ablation technique using intracardiac echocardiography (ICE) and electroanatomic mapping without fluoroscopy. METHODS AND RESULTS Twenty-one patients with atrial fibrillation (age, 42 to 7...

متن کامل

Use of the new contact force sensing ablation catheter dramatically reduces fluoroscopy time during atrial fibrillation ablation procedures

OBJECTIVES To study the impact of contact force (CF) sensing on fluoroscopy, procedure, left atrial (LA) and ablation times and number of ablations during atrial fibrillation (AF) ablation. BACKGROUND Catheter ablation is an effective treatment for symptomatic AF. Recently a new ablation catheter providing real-time CF has been approved for use. METHODS A nested case-control study was perfo...

متن کامل

A systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia

  Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system.   Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...

متن کامل

Three-dimensional image integration: a first experience with guidance of atrial fibrillation ablations.

The treatment of atrial fibrillation (AF) can be challenging, with a rate control strategy not being optimal for all patients and antiarrhythmic drugs frequently ineffective and possessing serious adverse effects. A fluoroscopic or electroanatomic catheter-based approach is rapidly becoming one of the preferred treatments of AF.1-3 However, success rates are still not ideal and complications du...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017