Pacemaker and implantable cardioverter defibrillator implantation without reversal of warfarin therapy.
نویسندگان
چکیده
The study evaluated all patients undergoing permanent pacemaker and ICD implantation over a 4-year period to determine if anticoagulated patients required normalization of coagulation factors in the periprocedural period. The study included 1,025 (597 men, 428 women, age 24-100 years, mean 72 years) consecutive patients who underwent device implantation using mostly a percutaneous subclavian approach. The procedures were performed without reversal of anticoagulation in 470 patients with INRs >or= 1.5 at the time of the procedure (mean INR 2.6 +/- 1.0, range 1.5-7.5). The complication rate in the anticoagulated group was similar to those in patients with a normal INR. Routine normalization of coagulation factors prior to pacemaker/ICD placement may not be necessary.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملPacemaker lead endocarditis with hiccups (Kalayci)
Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...
متن کاملAntithrombotic Therapy and Outcomes After ICD Implantation in Patients With Atrial Fibrillation and Coronary Artery Disease: An Analysis From the National Cardiovascular Data Registry (NCDR)®
BACKGROUND Management of antithrombotic agents after implantable cardioverter defibrillator implantation is challenging, particularly among patients with atrial fibrillation and coronary artery disease. METHODS AND RESULTS Using data from National Cardiovascular Data Registry(®) Implantable Cardioverter Defibrillator Registry(™) linked with Medicare claims data, we identified 25 180 patients ...
متن کاملAdverse Interactions between ICD and Permanent Pacemaker Systems
After the introduction of the implantable cardioverter defibrillator (ICD) in clinical practice by Mirowski in 1980 [Mirowski et al., 1980] the first available devices offered only a basic ventricular pacing option. Since approximately 5-20% of patients with an indication for ICD therapy following implantation criteria at that time (secondary prevention) needed antibradycardia pacing as well, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2004