The Mini-BESTest - a clinically reproducible tool for balance evaluations in mild to moderate Parkinson’s disease?

نویسندگان

  • Niklas Löfgren
  • Emma Lenholm
  • David Conradsson
  • Agneta Ståhle
  • Erika Franzén
چکیده

BACKGROUND The Mini-BESTest is a clinical balance test that has shown a high sensitivity in detecting balance impairments in elderly with Parkinson's disease (PD). However, its reproducibility between different raters and between test occasions has yet to be investigated in a clinical context. Moreover, no one has investigated the reproducibility of the Mini-BESTest's subcomponents (i.e. anticipatory postural adjustments; postural responses; sensory orientation and dynamic gait). We aimed to investigate the inter-rater and test-retest reproducibility (reliability as well as agreement) of the Mini-BESTest, as well as its subcomponents, in elderly with mild to moderate PD, performed under conditions assimilating clinical practice. METHOD This was an observational measurement study with a test-retest design. Twenty-seven individuals with idiopathic PD (66 - 80 years, mean age: 73; Hoehn & Yahr: 2-3; 1-15 years since diagnosis) were included. Two test administrators, having different experiences with the Mini-BESTest, administered the test individually, in separate rooms in a hospital setting. For the test-retest assessment, all participants returned 7 days after the first test session to perform the Mini-BESTest under similar conditions. Intra-class correlation coefficients (ICC2.1), standard error of measurement (SEMagreement), and smallest real difference (SRD) were analyzed. RESULTS The Mini-BESTest showed good reliability for both inter-rater and test-retest reproducibility (ICC = 0.72 and 0.80). Regarding agreement, the measurement error (SRD) was found to be 4.1 points (accounting for 15% of the maximal total score) for inter-rater reproducibility and 3.4 points (12% of the maximal total score) for test-retest reproducibility. The investigation of the Mini-BESTest's subcomponents showed a similar pattern for both inter-rater and test-retest reproducibility, where postural responses had the largest proportional measurement error, and sensory orientation showed the highest agreement. CONCLUSIONS Our findings indicate that the Mini-BESTest is able to distinguish between individuals with mild to moderate PD; however, when used in clinical balance assessments, the large measurement error needs to be accounted for.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

tHE MInI - BEStESt cAn PREdIct PARkInSonIAn REcuRREnt FAllERS : A 6 - MontH PRoSPEctIvE Study Margaret

J Rehabil Med 45 © 2013 The Authors. doi: 10.2340/16501977-1144 Journal Compilation © 2013 Foundation of Rehabilitation Information. ISSN 1650-1977 Objectives: To examine whether the Mini-Balance Evaluation Systems Test (Mini-BESTest) independently predicts recurrent falls in people with Parkinson’s disease. Design: The study used a longitudinal cohort design. Subjects: A total of 110 patients ...

متن کامل

Comparative utility of the BESTest, mini-BESTest, and brief-BESTest for predicting falls in individuals with Parkinson disease: a cohort study.

BACKGROUND The newly developed brief-balance evaluation system test (brief-BESTest) may be useful for measuring balance and predicting falls in individuals with Parkinson disease (PD). OBJECTIVES The purposes of this study were: (1) to describe the balance performance of those with PD using the brief-BESTest, (2) to determine the relationships among the scores derived from the 3 versions of t...

متن کامل

Comparing the Mini-BESTest with the Berg Balance Scale to Evaluate Balance Disorders in Parkinson's Disease

Objective. The purpose of this study was to explore the usefulness of the Mini-BESTest compared to the Berg Balance Scale in evaluating balance in people with PD of varying severity. We evaluated (1) the distribution of patients scores to look for ceiling effects, (2) concurrent validity with severity of disease, and (3) the sensitivity/specificity of separating people with or without postural ...

متن کامل

The Mini-Balance Evaluation Systems Test (Mini-BESTest) Demonstrates Higher Accuracy in Identifying Older Adult Participants With History of Falls Than Do the BESTest, Berg Balance Scale, or Timed Up and Go Test.

BACKGROUND AND PURPOSE Balance deficits a significant predictor of falls in older adults. The Balance Evaluation Systems Test (BESTest) and the Mini-Balance Evaluation Systems Test (Mini-BESTest) are tools that may predict the likelihood of a fall, but their capabilities and accuracies have not been adequately addressed. Therefore, this study aimed at examining the capabilities of the BESTest a...

متن کامل

The mini-BESTest can predict parkinsonian recurrent fallers: a 6-month prospective study.

OBJECTIVES To examine whether the Mini-Balance Evaluation Systems Test (Mini-BESTest) independently predicts recurrent falls in people with Parkinson's disease. DESIGN The study used a longitudinal cohort design. SUBJECTS A total of 110 patients with Parkinson's disease completed the study and were included in the final analysis. Most of the patients had moderate disease severity. METHODS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014