3-D real-time motion correction in high-intensity focused ultrasound therapy.

نویسندگان

  • Mathieu Pernot
  • Mickaël Tanter
  • Mathias Fink
چکیده

A method for tracking the 3-D motion of tissues in real-time is combined with a 2-D high-intensity focused ultrasound (US), or HIFU, multichannel system to correct for respiratory motion during HIFU therapy. Motion estimation is based on an accurate ultrasonic speckle-tracking method. A pulse-echo sequence is performed for a subset of the transducers of the phased array. For each of these subapertures, the displacement is estimated by computing the 1-D cross-correlation of the backscattered signals acquired at two different times. The 3-D motion vector is then computed by a triangulation algorithm. This technique is experimentally validated in phantoms moving as fast as 40 mm s(-1), and combined with HIFU sequences. A real-time feedback correction of the HIFU beam is achieved by adjusting the delays of each channel. The sonications "locked on target" are interleaved with very short motion-estimation sequences. Finally, in vitro experiments of "locked on target" HIFU therapy are performed in fresh moving tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A framework for continuous target tracking during MR-guided high intensity focused ultrasound thermal ablations in the abdomen

BACKGROUND During lengthy magnetic resonance-guided high intensity focused ultrasound (MRg-HIFU) thermal ablations in abdominal organs, the therapeutic work-flow is frequently hampered by various types of physiological motion occurring at different time-scales. If left un-addressed this can lead to an incomplete therapy and/or to tissue damage of organs-at-risk. While previous studies focus on ...

متن کامل

High Intensity Focused Ultrasound Therapy Combined with 3d Real Time Tracking Motion System

For optimal treatment conditions, patient motion, particularly respiratory motion, must be monitored and corrected during HIFU treatments. We propose here a new generation of multi-channel HIFU systems able to track and correct in real-time the 3D motion of tissues. It is based on an accurate ultrasonic speckle tracking method for both following and compensating the motion of the tumor. The dis...

متن کامل

Optimization of volumetric MR-guided high-intensity focused ulatrsound ablations in moving organs

Introduction In this work, a method for the optimization of volumetric MR-guided high intensity focused ultrasound (HIFU) ablations is presented. While commonly MRguidance of thermal therapies is based on temperature control the on-line assessment of the thermal dose has been suggested to determine the therapy endpoint [1]. Therefore, we propose to monitor the thermal dose [2] of the treated ti...

متن کامل

A Reliable Real Time Liver Motion Tracking for Application in Magnetic Resonance guided High Intensity Focused Ultrasound Therapy

Introduction High-intensity focused ultrasound has shown potential for ablating liver tumors without the need for surgical procedures [1]. However, the long duration of HIFU scans (~2hrs) and the varying respiratory motion requires that features identified for sonication be tracked in real time during the procedure [2]. The real time tracking would enable a free-breathing MRgFUS treatment and t...

متن کامل

Thermal ablation of a confluent lesion in the porcine kidney with magnetic resonance guided high intensity focused ultrasound

Background/introduction Since approximately 1.6 percent of men and women will be diagnosed with kidney and renal pelvis cancer during their lifetime, there is a growing interest in non-invasive kidney sparing therapy for renal cancer. As a consequence, several patient studies investigated the feasibility of high intensity focused ultrasound (HIFU) for the thermal ablation of renal masses. The m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 30 9  شماره 

صفحات  -

تاریخ انتشار 2004