A miniscrew system with interchangeable abutments.

نویسندگان

  • Benedict Wilmes
  • Dieter Drescher
چکیده

JCO/OCTOBER 2008 O miniscrews have become increasingly popular in recent years because of their versatility, minimal invasiveness, and low cost. The effectiveness of conventional miniscrew systems is limited, however, by the lack of a stable connection to the orthodontic appliance. The Straumann Orthosystem* addresses this problem with a cap or abutment that can be fixed to the implant. The system can be used as anchorage for distalization of the maxillary molars or for mesial space closure, but is more costly than conventional miniscrews in terms of both direct expense and chairtime. Moreover, a three-month healing period is recommended after placement of an Orthosystem implant before force loading. As an alternative, we developed the Benefit** miniimplant system with interchangeable abutments (Fig. 1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A miniplate system for improved stability of skeletal anchorage.

miniscrews reportedly have failure rates as high as 10-30%.1-4 Miniscrew loosening or tipping can result from any of the following factors: • Insufficient bone quantity or quality at the insertion site.5-7 • Use of a screw of inadequate diameter or length.3,8-10 • Inappropriate intraosseous design.10-12 • Root contact during insertion.13 • Manipulation by the patient’s fingers or tongue.8 • Poo...

متن کامل

Screw loosening with interchangeable abutments in internally connected implants after cyclic loading.

PURPOSE The purpose of this study was to observe and compare any loosening of screws attaching several interchangeable abutments to internally connected implants after cyclic loading. MATERIALS AND METHODS Four different abutment groups mated with Straumann single-stage transmucosal implants (n = 7 each group) were assessed: Straumann solid abutment, Restore COC abutment, Neoplant solid abutm...

متن کامل

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

Evaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study

BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this stu...

متن کامل

Effect of force on alveolar bone surrounding miniscrew implants: a 3-dimensional microcomputed tomography study.

INTRODUCTION The primary aim of this study was to better understand how bone adapts to forces applied to miniscrew implants. A secondary aim was to determine whether the direction of force applied to miniscrew implants has an effect on bone surrounding the miniscrew implants. METHODS A randomized split-mouth design, applied to 6 skeletally mature male foxhound dogs, was used to compare minisc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical orthodontics : JCO

دوره 42 10  شماره 

صفحات  -

تاریخ انتشار 2008