Absence of clinical pneumonia following bronchoscopy with contaminated and clean bronchofiberscopes.

نویسندگان

  • P M Suratt
  • B Gruber
  • H A Wellons
  • R P Wenzel
چکیده

Two hundred forty-nine fiberoptic bronchoscopy procedures were surveyed for the presence of bronchoscopy-related pneumonia. The first 103 procedures were performed during a period when the fiberscope was presemably contaminated with Pseudomonas aeruginosa. Chart review of these 103 procedures and prospective epidemiologic surveillance of the remaining 146 procedures revealed no cases of bronchoscopy-related pneumonia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case of Pulmonary Foreign Body Reviewed as Mass

Foreign Body Aspiration (FBA) is a common and sometimes life-threatening problem in children and in higher age groups. FBA highest incidence rate is during the second year in children and the sixth decade of life in adults, and often foreign bodies due to their shape and size pass through larynx and trachea and place in bronchi. The most common aspirated body by children are nuts. Symptoms of a...

متن کامل

Co- infectious Cytomegalovirus and Pneumocystis Jiroveci Pneumonia in a Polyarteritis Nodosa Patient: A Case Report

Our report discusses a patient diagnosed with PAN since 3 years ago. He presented with fever, chills and nonproductive cough. He was a long time receiver of immunosuppressant drugs for his underlying condition. Upon examination he was febrile, had cushingoid appearance and cackles in both lungs. Lung CT scan showed opacities in right upper lobe lung and multiple bilateral nodules and ground gla...

متن کامل

A Clinical Profile of Chronic Bacterial Pneumonia*

Objective: To review the clinical presentation, radiology, microbiology, and response to therapy of patients with chronic bacterial pneumonia. Design: A retrospective analysis. Setting: An urban tertiary care medical center. Participants: One hundred fifteen patients with pulmonary and/or constitutional symptoms of at least 1 month's duration with 4,000 or more colony-forming units (CFUs) of a ...

متن کامل

Clinical impact of early bronchoscopy in mechanically ventilated patients with aspiration pneumonia

BACKGROUND AND OBJECTIVE A handful of studies have reported that bronchoscopies influence the clinical outcome of mechanically ventilated patients with aspiration pneumonia. The purpose of the present study is to elucidate the therapeutic role of early bronchoscopy in patients with aspiration who are mechanically ventilated. METHODS A retrospective cohort study was conducted via medical recor...

متن کامل

Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy.

Flexible endoscopy is a widely used diagnostic and therapeutic procedure. Contaminated endoscopes are the medical devices frequently associated with outbreaks of health care-associated infections. Accurate reprocessing of flexible endoscopes involves cleaning and high-level disinfection followed by rinsing and drying before storage. Most contemporary flexible endoscopes cannot be heat sterilize...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 71 1  شماره 

صفحات  -

تاریخ انتشار 1977