Sensitivity to implant materials in patients with total knee arthroplasties.
نویسندگان
چکیده
Materials used for total knee arthroplasty (TKA), may elicit an immune response whose role in the outcome of the arthroplasty is still unclear. The aim of this study was to evaluate the frequency of sensitization in patients who had undergone TKA, and the clinical impact of this event on the outcome of the implant. Ninety-four subjects were recruited, including 20 patients who had not yet undergone arthroplasty, 27 individuals who had a well-functioning TKA, and 47 patients with loosening of TKA components. Sensitization was detected by using patch testing including haptens representative of cobalt-based alloys (CoCrMo), titanium-based alloys (TiAlV), and bone cements. The frequency of positive skin reactions to metals increased significantly after TKA, either stable or loosened (No Implant 20%; Stable TKA 48.1%, p=0.05; Loosened TKA 59.6%, p=0.001, respectively). We found a higher frequency of positive patch testing to vanadium in patients who had a Stable TKA with at least one TiAlV component (39.1%, p=0.01). The medical history for metal allergy seems to be a risk factor, because the TKA failure was fourfold more likely in patients who had symptoms of metal hypersensitivity before TKA. The prognostic value was supported by survival analysis, because in these individuals the outcome of the implant was negatively influenced (the logrank test Chi square 5.1, p=0.02). This study confirms that in patients with a TKA the frequency of positive patch testing is higher than in the normal population, although no predictive value is attributable to the sensitization because patch testing was not able to discriminate between stable and loose implants. On the contrary, the presence of symptoms of metal allergy before implantation should be taken into account as a potential risk factor for TKA failure.
منابع مشابه
Failure of aseptic revision total knee arthroplasties
BACKGROUND AND PURPOSE In Norway, the proportion of revision knee arthroplasties increased from 6.9% in 1994 to 8.5% in 2011. However, there is limited information on the epidemiology and causes of subsequent failure of revision knee arthroplasty. We therefore studied survival rate and determined the modes of failure of aseptic revision total knee arthroplasties. METHOD This study was based o...
متن کاملOutcome of revision in comparison with primary total knee arthroplasty in Iran
Abstract Background: In the recent decade, many primary total knee arthroplasties have been carried out in Iran and the number of revision cases is expected to rise with the aging population. The aim of this study was to report the outcome of revision surgery in the country and make a comparison between the outcome of revision and that of the primary arthroplasty. Methods: Retrospectivel...
متن کاملC-Reactive Protein, Erythrocyte Sedimentation Rate and Orthopedic Implant Infection
BACKGROUND C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) have been shown to be useful for diagnosis of prosthetic hip and knee infection. Little information is available on CRP and ESR in patients undergoing revision or resection of shoulder arthroplasties or spine implants. METHODS/RESULTS We analyzed preoperative CRP and ESR in 636 subjects who underwent knee (n=297), hi...
متن کاملTotal Knee Replacement Sizing: Shoe Size Is a Better Predictor for Implant Size than Body Height
Background: Various sizes of implants need to be available during surgery. The purpose of this paper is to comparebody height and shoe size with implant sizes in patients who underwent total knee replacement surgery to see whichbiomarker is a better predictor for preoperative planning to determine implant size.Methods: A total of 100 knees, belonging to 50 females and 50 males, were observed. P...
متن کاملEndo-Modell rotating-hinge total knee for revision total knee arthroplasty.
The goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge pr...
متن کاملBetter Survival of Total Knee Replacement in Patients Older Than 70 Years: A Prospective Study with 8 To 12 Years Follow-Up
Background: Modern knee designs have popularized its use in younger patients due to its better performance. There remains uncertainty whether higher demands of these patients can affect implant survivorship. Purpose: To assess whether modern knee designs have provided similar results in patients younger than 70 years versus older patients. Methods: We included 203 consecutive patients (236 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomaterials
دوره 29 10 شماره
صفحات -
تاریخ انتشار 2008