INRIM facilities for HIFU field characterization

نویسندگان

  • Giovanni Durando
  • Claudio Guglielmone
  • Chiara Magnetto
چکیده

HIFU power measurement At ultrasonic laboratory of INRIM (Istituto Nazionale di Ricerca Metrologica) it is possible to measure the ultrasonic power emitted by HIFU (High Intesity Focused Ultrasound) transducers. Two different measuring systems for the determination of ultrasonic power have been developed. Both systems are based on the radiation force balance method. The first system is based on a commercial balance (RFB System) and is used for ultrasonic power from 100 mW to 20 W. The ultrasonic power, P , is determined from the measurement of the force exerted on a target by the sound field generated by an ultrasonic source (figure 1). The second system is based on a submersible load cell (SLC), with full scale sensitivity of 50 g, and it is used for measuring of ultrasonic power from 15 W to 200 W.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acoustic Field Comparison of High Intensity Focused Ultrasound Using Experimental Characterization and Finite Element Simulation

Introduction: High Intensity Focused Ultrasound (HIFU) is a technique currently used for different medical treatments such as thermal ablation, hyperthermia, and bleeding control [1]. This kind of technique is based on the use of an acoustic transducer with a concave face used to focus the ultrasound energy in a specific zone (Figure 1). The acoustic field characterization in transducers is imp...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

[Proceeding] The INRiM thermo-hydraulic mock-up for thermal energy measurement devices: Design, construction and metrological characterization

At the National Institute of Metrological Research (INRiM), the first European thermo-hydraulic simulator (mock-up) for testing both traditional and innovative thermal energy measurement devices and heat cost allocators has been recently built up, in the context of the EU Seventh Framework Programme FP7-SME-2012. The INRiM mock-up is an automatically reconfigurable thermo-hydraulic circuit equi...

متن کامل

Temperature effect in high intensity focused ultrasound therapy control using dynamic MR elastography

High intensity focused ultrasound (HIFU) is a method for non-invasive tumor therapy. The high energy density in the focal spot leads to local tissue heating and finally to thermal coagulation in the focal area (Fig.1) [1]. To monitor this treatment, the focus position can be detected online with temperature sensitive MR imaging. However characterization of the induced lesion is difficult. It ha...

متن کامل

Characterization of high intensity focused ultrasound transducers using acoustic streaming.

A new approach for characterizing high intensity focused ultrasound (HIFU) transducers is presented. The technique is based upon the acoustic streaming field generated by absorption of the HIFU beam in a liquid medium. The streaming field is quantified using digital particle image velocimetry, and a numerical algorithm is employed to compute the acoustic intensity field giving rise to the obser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014