Simulation of magnetic circular dichroism in the electron microscope

نویسندگان

  • Stefano Rubino
  • Peter Schattschneider
  • Jan Rusz
  • Johan Verbeeck
  • Klaus Leifer
چکیده

As Electron Energy-Loss Spectroscopy (EELS) and X-ray Absorption Spectroscopy (XAS) probe the same transitions from core-shell states to unoccupied states above the Fermi energy, it should be always possible to apply the two techniques to the same physical phenomena, such as magnetic dichroism, and obtain the same information. Indeed, the similarity in the expression of the electron and x-ray crosssections had been already exploited to prove the equivalence of X-ray Magnetic Linear Dichroism (XMLD) and anisotropy in EELS, by noting that the polarization vector of a photon plays the same role as the momentum transfer in electron scattering. Recently, the same was proven true for X-ray Magnetic Circular Dichroism (XMCD) by establishing a new TEM technique called EMCD (Electron energy-loss Magnetic Chiral Dichroism) [1], which makes use of special electron scattering conditions to force the absorption of a circularly polarized virtual photon. The intrinsic advantage of EMCD over XMCD is the high spatial resolution of electron microscopes, which are readily available. Among the particular obstacles in EMCD that do not exist for synchrotron radiation is the notoriously low signal and the very particular scattering conditions necessary to observe a chiral dichroic signal. In spite of that, impressive progress was made in the last years. The signal strength could be considerably increased, and some innovations such as using a convergent beam have been introduced. EMCD has evolved into several techniques, which make full use of the versatility of the TEM and energy filtering, spectroscopy or STEM conditions [2]. Simulation of magnetic circular dichroism in the electron microscope 2

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EMCD - Magnetic Chiral Dichroism in the Electron Microscope

The discovery of energy loss magnetic chiral dichroism (EMCD) has created a new approach to element specific magnetic measurements with highest spatial resolution [1]. EMCD, which is detected in the fine structure of energy loss spectra in a transmission electron microscope (TEM) probes the same electronic transitions as its well established X-ray counterpart, the X-ray magnetic circular dichro...

متن کامل

Magnetic Circular Dichroism in Electron Microscopy

Although the analogies between the electron energy loss spectra and X-ray absorption spectra were recognized long ago, the possibility to observe the magnetic circular dichroism in the electron microscope was demonstrated only recently. This technique combines the atom specificity with the high spatial resolution of the transmission electron microscope. Being a very young technique, there are s...

متن کامل

An in-plane magnetic chiral dichroism approach for measurement of intrinsic magnetic signals using transmitted electrons

Electron energy-loss magnetic chiral dichroism is a powerful technique that allows the local magnetic properties of materials to be measured quantitatively with close-to-atomic spatial resolution and element specificity in the transmission electron microscope. Until now, the technique has been restricted to measurements of the magnetic circular dichroism signal in the electron beam direction. H...

متن کامل

Magnetic measurements with atomic-plane resolution

Rapid development of magnetic nanotechnologies calls for experimental techniques capable of providing magnetic information with subnanometre spatial resolution. Available probes of magnetism either detect only surface properties, such as spin-polarized scanning tunnelling microscopy, magnetic force microscopy or spin-polarized low-energy electron microscopy, or they are bulk probes with limited...

متن کامل

Magnetic dichroisms in absorption and photoemission for magnetic characterization in x-ray photoelectron emission microscopy

Magnetic contrast for the operation of a photoelectron emission microscope ~PEEM! with synchrotron radiation is provided by magnetic dichroisms. Besides the most frequently employed magnetic dichroism, magnetic circular dichroism in x-ray absorption spectroscopy, energy filtering of photoemitted electrons allows one to also use magnetic dichroisms in photoelectron emission as complementary cont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010