Lateral flow microarrays: a novel platform for rapid nucleic acid detection based on miniaturized lateral flow chromatography

نویسندگان

  • Darren J. Carter
  • R. Bruce Cary
چکیده

Widely used nucleic acid assays are poorly suited for field deployment where access to laboratory instrumentation is limited or unavailable. The need for field deployable nucleic acid detection demands inexpensive, facile systems without sacrificing information capacity or sensitivity. Here we describe a novel microarray platform capable of rapid, sensitive nucleic acid detection without specialized instrumentation. The approach is based on a miniaturized lateral flow device that makes use of hybridization-mediated target capture. The miniaturization of lateral flow nucleic acid detection provides multiple advantages over traditional lateral flow devices. Ten-microliter sample volumes reduce reagent consumption and yield analyte detection times, excluding sample preparation and amplification, of <120 s while providing sub-femtomole sensitivity. Moreover, the use of microarray technology increases the potential information capacity of lateral flow. Coupled with a hybridization-based detection scheme, the lateral flow microarray (LFM) enables sequence-specific detection, opening the door to highly multiplexed implementations for broad-range assays well suited for point-of-care and other field applications. The LFM system is demonstrated using an isothermal amplification strategy for detection of Bacillus anthracis, the etiologic agent of anthrax. RNA from as few as two B. anthracis cells was detected without thermocycling hardware or fluorescence detection systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Capillary-driven Microfluidic Device for Rapid Dna Detection with Extremely Low Sample Consumption

This paper reports a novel silicon based lateral flow device for DNA hybridization detection. The device applies microfabricated micropillar array to generate capillary flow with controllable capillary flow rates. A rapid DNA hybridization detection was demonstrated within 1 min with extremely low sample consumption

متن کامل

A novel, universal and sensitive lateral-flow based method for the detection of multiple bacterial contamination in platelet concentrations.

In the present study, we aimed to develop a nucleic acid lateral-flow method for the rapid and sensitive detection of multiple bacteria that contaminate platelet concentrations (PCs). Polymerase chain reaction (PCR) amplicons were produced by a set of board-range primers that recognize the conserved region of bacteria 16S rDNA, followed by hybridization with both an FITC (fluorescein isothiocy...

متن کامل

Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies

Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...

متن کامل

Development of Chemiluminescent Lateral Flow Assay for the Detection of Nucleic Acids

Rapid, sensitive detection methods are of utmost importance for the identification of pathogens related to health and safety. Herein we report the development of a nucleic acid sequence-based lateral flow assay which achieves a low limit of detection using chemiluminescence. On-membrane enzymatic signal amplification is used to reduce the limit of detection to the sub-femtomol level. To demonst...

متن کامل

Flow cytometry for microbial sensing in environmental sustainability applications: current status and future prospects.

Practical and accurate microbial assessment of environmental systems is predicated on the detection and quantification of various microbial parameters in complex matrices. Traditional growth-based assays, considered to be both slow and biased, are increasingly being replaced by optical detection methods such as flow cytometry. Flow cytometry (FCM) offers high-speed multi-parametric data acquisi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2007