Considerations for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion.

نویسندگان

  • Stephen J Rebscher
  • Alexander Hetherington
  • Ben Bonham
  • Peter Wardrop
  • David Whinney
  • Patricia A Leake
چکیده

The level of hearing rehabilitation enjoyed by cochlear implant (CI) recipients has increased dramatically since the introduction of these devices. This improvement is the result of continual development of these systems and the inclusion of subjects with less severe auditory pathology. Developments include advanced signal processing, higher stimulation rates, greater numbers of channels, and more efficient electrode arrays that are less likely to produce insertion damage. New directions in the application of CIs, particularly in combined acoustic and electrical stimulation, and increasing performance expectations will place greater demands on future electrode arrays. Specifically, the next generation of arrays must be reliably inserted without damage, must maintain residual acoustic function, and may need to be inserted more deeply. In this study, we measured the mechanical properties of eight clinical and prototype human CI electrode arrays and evaluated insertion trauma and insertion depth in 79 implanted cadaver temporal bones. We found that the size and shape of the array directly affect the incidence of observed trauma. Further, arrays with greater stiffness in the plane perpendicular to the plane of the cochlear spiral are less likely to cause severe trauma than arrays with similar vertical and horizontal stiffness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

The use of micro-CT to evaluate cochlear implant electrode position and intracochlear damage.

1. Balkany TJ, Connell SS, Hodges AVet al. Conservation of residual acoustic hearing after cochlear implantation. Otol Neurotol 2006;27:1083-8. 2. von Ilberg C, Kiefer J, Tillein Jet al. Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss. ORL; journal for oto-rhino-laryngology and its related specialties 1999;61:334-40. 3. Gantz BJ, Turner CW. Combining...

متن کامل

Electrode interaction in cochlear implant recipients: comparison of straight and contour electrode arrays.

The degree of overlap among cochlear nerve fibers stimulated by different electrodes results in electrode interaction, which has been shown to have a significantly deleterious effect on speech recognition performance in multi-electrode cochlear implant users. The Nucleus CI24R(CS) Contour array, which lies substantially closer to the modiolus than the CI24M straight array, is expected to exhibi...

متن کامل

An overview of cochlear implant electrode array designs

Cochlear implant electrode arrays are designed with specific characteristics that allow for the preservation of intra-cochlear structures during the insertion process, as well as during explantation. Straight lateral wall (LW) electrode arrays and pre-curved modiolar hugging (MH) electrode arrays are the two types that are commercially available. Although there is a third type of electrode arra...

متن کامل

Path Planning and Workspace Determination for Robot-Assisted Insertion of Steerable Electrode Arrays for Cochlear Implant Surgery

In previous works, the authors showed that using robot-assisted steerable electrode array insertions can significantly reduce the insertion forces compared to non-steerable electrode arrays. In addition to steering the electrode array, it is possible to change its angle of approach with respect to the scala tympani. This paper focuses on determining the relevance of changing the angle of approa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 45 5  شماره 

صفحات  -

تاریخ انتشار 2008