Superior GRAPPA reconstruction with reduced g-factor noise using 2D CAIPIRINHA for 3D EPI

نویسندگان

  • Mayur Narsude
  • José P. Marques
  • Daniel Gallichan
  • Rolf Gruetter
چکیده

different Δ shifts (A=0, B=3, C=2) in the slice encode direction for one sampling row Ky to the next. Corresponding k-space sampling patterns are also shown. All points belonging to a particular segment are acquired during a single readout echo train. Missing k-space points are empty squares whereas filled squares are acquired k-space points. Note that the length of the echo train is kept unchanged.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of temporal signal-to-noise ratio of GRAPPA accelerated echo planar imaging using a FLASH based calibration scan.

PURPOSE To demonstrate that the temporal signal-to-noise ratio (SNR) of generalized autocalibrating partially parallel acquisitions (GRAPPA) accelerated echo planar imaging (EPI) can be enhanced and made more spatially uniform by using a fast low angle shot (FLASH) based calibration scan. METHODS EPI of a phantom and human brains were acquired at 3 Tesla without and with GRAPPA acceleration f...

متن کامل

A 3D GRAPPA algorithm for volumetric parallel imaging

Introduction: In volumetric parallel imaging, data reduction is carried out along two phase encoding directions, thereby exploiting sensitivity variations in two spatial dimensions and yielding improved parallel imaging reconstruction performance. In previous work, imagedomain based two-dimensional SENSE reconstruction methods have been presented for rectangular [1] and 2D CAIPIRINHA-type reduc...

متن کامل

Stack-of-Spirals CAIPIRINHA Trajectory for Rapid Volumetric Imaging

Target Audience: MRI physicists and engineers. Purpose: The stack-of-spirals trajectory has been shown to be a very time efficient method to traverse a volumetric k-space for high-resolution imaging (1). Rapid volumetric imaging is useful for high-resolution fMRI at high magnetic fields (2). The long scan times needed for high resolutions however can compromise the temporal resolution of the BO...

متن کامل

Accelerated Simultaneous Multi-slice Cardiac Cine Imaging Using a Combination of CAIPIRINHA and Compressed Sensing

images of the two simultaneously excited slices. Displayed are (a) the conventional reconstruction of the CAIPIRINHA acquisition using GRAPPA and (b) the reconstruction of the incoherently undersampled CAIPIRINHA acquisition using the proposed combination of Compressed Sensing and GRAPPA. (c) Difference between a) and b) magnified by a factor of 10. Accelerated Simultaneous Multi-slice Cardiac ...

متن کامل

Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging.

PURPOSE The purpose of this study was to evaluate the feasibility and technical quality of an abdominal 3-dimensional interpolated breath-hold (volumetric interpolated breath-hold examination [VIBE]) magnetic resonance examination using the new parallel acquisition technique, controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA). MATERIALS AND METHODS In this ins...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012