Pregnancy Does Not Affect HIV Incidence Test Results Obtained Using the BED Capture Enzyme Immunoassay or an Antibody Avidity Assay

نویسندگان

  • Oliver Laeyendecker
  • Jessica D. Church
  • Amy E. Oliver
  • Anthony Mwatha
  • S. Michele Owen
  • Deborah Donnell
  • Ron Brookmeyer
  • Philippa Musoke
  • J. Brooks Jackson
  • Laura Guay
  • Clemesia Nakabiito
  • Thomas C. Quinn
  • Susan H. Eshleman
چکیده

BACKGROUND Accurate incidence estimates are needed for surveillance of the HIV epidemic. HIV surveillance occurs at maternal-child health clinics, but it is not known if pregnancy affects HIV incidence testing. METHODS We used the BED capture immunoassay (BED) and an antibody avidity assay to test longitudinal samples from 51 HIV-infected Ugandan women infected with subtype A, C, D and intersubtype recombinant HIV who were enrolled in the HIVNET 012 trial (37 baseline samples collected near the time of delivery and 135 follow-up samples collected 3, 4 or 5 years later). Nineteen of 51 women were also pregnant at the time of one or more of the follow-up visits. The BED assay was performed according to the manufacturer's instructions. The avidity assay was performed using a Genetic Systems HIV-1/HIV-2 + O EIA using 0.1M diethylamine as the chaotropic agent. RESULTS During the HIVNET 012 follow-up study, there was no difference in normalized optical density values (OD-n) obtained with the BED assay or in the avidity test results (%) when women were pregnant (n = 20 results) compared to those obtained when women were not pregnant (n = 115; for BED: p = 0.9, generalized estimating equations model; for avidity: p = 0.7, Wilcoxon rank sum). In addition, BED and avidity results were almost exactly the same in longitudinal samples from the 18 women who were pregnant at only one study visit during the follow-up study (p = 0.6, paired t-test). CONCLUSIONS These results from 51 Ugandan women suggest that any changes in the antibody response to HIV infection that occur during pregnancy are not sufficient to alter results obtained with the BED and avidity assays. Confirmation with larger studies and with other HIV subtypes is needed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Recency Period for Estimation of Human Immunodeficiency Virus Incidence by the AxSYM Avidity Assay and BED-Capture Enzyme Immunoassay in the Republic of Korea

OBJECTIVES Measurement of the incidence of the human immunodeficiency virus (HIV) is very important for epidemiological studies. Here, we determined the recency period with the AxSYM avidity assay and the BED-capture enzyme immunoassay (BED-CEIA) in Korean seroconverters. METHODS Two hundred longitudinal specimens from 81 seroconverters with incident HIV infections that had been collected at ...

متن کامل

Improved Testing of Recent HIV-1 Infections with the BioRad Avidity Assay Compared to the Limiting Antigen Avidity Assay and BED Capture Enzyme Immunoassay: Evaluation Using Reference Sample Panels from the German Seroconverter Cohort

BACKGROUND The variety and limitations of current laboratory methods for estimating HIV-incidence has driven attempts to improve and standardize the performance of serological 'Tests for Recent HIV-Infections' (TRI). Primary and follow-up HIV-1 positive plasma samples from individuals with well-defined dates of infection collected as part of the German Seroconverter Cohort provided specimens hi...

متن کامل

The Effect of Sample Handling on Cross Sectional HIV Incidence Testing Results

OBJECTIVE(S) To determine if mishandling prior to testing would make a sample from a chronically infected subject appear recently infected when tested by cross-sectional HIV incidence assays. METHODS Serum samples from 31 subjects with chronic HIV infection were tested. Samples were subjected to different handling conditions, including incubation at 4 °C, 25 °C and 37 °C, for 1, 3, 7 or 15 da...

متن کامل

Performance of a Limiting-Antigen Avidity Enzyme Immunoassay for Cross-Sectional Estimation of HIV Incidence in the United States

BACKGROUND A limiting antigen avidity enzyme immunoassay (HIV-1 LAg-Avidity assay) was recently developed for cross-sectional HIV incidence estimation. We evaluated the performance of the LAg-Avidity assay alone and in multi-assay algorithms (MAAs) that included other biomarkers. METHODS AND FINDINGS Performance of testing algorithms was evaluated using 2,282 samples from individuals in the U...

متن کامل

Specificity of four laboratory approaches for cross-sectional HIV incidence determination: analysis of samples from adults with known nonrecent HIV infection from five African countries.

Assays to determine cross-sectional HIV incidence misclassify some individuals with nonrecent HIV infection as recently infected, overestimating HIV incidence. We analyzed factors associated with false-recent misclassification in five African countries. Samples from 2197 adults from Botswana, Kenya, South Africa, Tanzania, and Uganda who were HIV infected > 12 months were tested using the (1) B...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -