Intra-Tissue Pressure Measurement in Ex Vivo Liver Undergoing Laser Ablation with Fiber-Optic Fabry-Perot Probe
نویسندگان
چکیده
We report the first-ever intra-tissue pressure measurement performed during 1064 nm laser ablation (LA) of an ex vivo porcine liver. Pressure detection has been performed with a biocompatible, all-glass, temperature-insensitive Extrinsic Fabry-Perot Interferometry (EFPI) miniature probe; the proposed methodology mimics in-vivo treatment. Four experiments have been performed, positioning the probe at different positions from the laser applicator tip (from 0.5 mm to 5 mm). Pressure levels increase during ablation time, and decrease with distance from applicator tip: the recorded peak parenchymal pressure levels range from 1.9 kPa to 71.6 kPa. Different pressure evolutions have been recorded, as pressure rises earlier in proximity of the tip. The present study is the first investigation of parenchymal pressure detection in liver undergoing LA: the successful detection of intra-tissue pressure may be a key asset for improving LA, as pressure levels have been correlated to scattered recurrences of tumors by different studies.
منابع مشابه
Fiber-optic combined FPI/FBG sensors for monitoring of radiofrequency thermal ablation of liver tumors: ex vivo experiments.
We present a biocompatible, all-glass, 0.2 mm diameter, fiber-optic probe that combines an extrinsic Fabry-Perot interferometry and a proximal fiber Bragg grating sensor; the probe enables dual pressure and temperature measurement on an active 4 mm length, with 40 Pa and 0.2°C nominal accuracy. The sensing system has been applied to monitor online the radiofrequency thermal ablation of tumors i...
متن کاملFiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation
An optical fiber current sensor based on Fabry-Perot interferometer using a fiber Bragg grating demodulation is proposed. Magnetic fluid is used as a sensitive medium in fiber optical Fabry-Perot (F-P) cavity for the optical characteristic of magnetic-controlled refractive index. A Fiber Bragg grating (FBG) is connected after the F-P interferometer which is used to reflect the optical power at ...
متن کاملHigh-pressure and high-temperature characteristics of a Fabry-Perot interferometer based on photonic crystal fiber.
A fiber-optic Fabry-Perot interferometer was constructed by splicing a short length of photonic crystal fiber to a standard single-mode fiber. The photonic crystal fiber functions as a Fabry-Perot cavity and serves as a direct sensing probe without any additional components. Its pressure and temperature responses in the range of 0-40 MPa and 25°C-700°C were experimentally studied. The proposed ...
متن کاملA Fiber Optic Fabry–Perot Cavity Sensor for the Probing of Oily Samples
A micro-optical Fabry–Perot cavity fabricated by non-linear laser lithography on the endface of a standard telecom fiber is tested here as a microsensor for identifying oily liquids. The device operates within the 1550 nm spectral region, while the spectra recorded in reflection mode correlate to the refractive index of the oily liquids used, as well as, to the diffusion dynamics in the time do...
متن کاملFiber optic extrinsic Fabry-Perot interferometric sensor for high blast pressure measurement
Optical fiber based Extrinsic Fabry-Perot Interferometric (EFPI) sensor significantly emerged as an advanced optical sensor for the health monitoring of civil, mechanical and aeronautical structures. This sensor responds its well capability also towards the measurement of acoustic/shock wave pressure. This paper presents an approach for high blast (acoustic/shock wave) pressure measurement usin...
متن کامل