A unified statistical framework for material decomposition using multienergy photon counting x-ray detectors.

نویسندگان

  • Jiyoung Choi
  • Dong-Goo Kang
  • Sunghoon Kang
  • Younghun Sung
  • Jong Chul Ye
چکیده

PURPOSE Material decomposition using multienergy photon counting x-ray detectors (PCXD) has been an active research area over the past few years. Even with some success, the problem of optimal energy selection and three material decomposition including malignant tissue is still on going research topic, and more systematic studies are required. This paper aims to address this in a unified statistical framework in a mammographic environment. METHODS A unified statistical framework for energy level optimization and decomposition of three materials is proposed. In particular, an energy level optimization algorithm is derived using the theory of the minimum variance unbiased estimator, and an iterative algorithm is proposed for material composition as well as system parameter estimation under the unified statistical estimation framework. To verify the performance of the proposed algorithm, the authors performed simulation studies as well as real experiments using physical breast phantom and ex vivo breast specimen. Quantitative comparisons using various performance measures were conducted, and qualitative performance evaluations for ex vivo breast specimen were also performed by comparing the ground-truth malignant tissue areas identified by radiologists. RESULTS Both simulation and real experiments confirmed that the optimized energy bins by the proposed method allow better material decomposition quality. Moreover, for the specimen thickness estimation errors up to 2 mm, the proposed method provides good reconstruction results in both simulation and real ex vivo breast phantom experiments compared to existing methods. CONCLUSIONS The proposed statistical framework of PCXD has been successfully applied for the energy optimization and decomposition of three material in a mammographic environment. Experimental results using the physical breast phantom and ex vivo specimen support the practicality of the proposed algorithm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental comparison of empirical material decomposition methods for spectral CT.

Material composition can be estimated from spectral information acquired using photon counting x-ray detectors with pulse height analysis. Non-ideal effects in photon counting x-ray detectors such as charge-sharing, k-escape, and pulse-pileup distort the detected spectrum, which can cause material decomposition errors. This work compared the performance of two empirical decomposition methods: a...

متن کامل

Evaluation of models of spectral distortions in photon-counting detectors for computed tomography.

A semi-analytical model describing spectral distortions in photon-counting detectors (PCDs) for clinical computed tomography was evaluated using simulated data. The distortions were due to count rate-independent spectral response effects and count rate-dependent pulse-pileup effects and the model predicted both the mean count rates and the spectral shape. The model parameters were calculated us...

متن کامل

A Radon-based criterion for the energy resolution of photon counting x-ray detectors

Thanks to recent developments in photon counting detectors, X-Ray spectral imaging has received increasing attention. This technique permits the quanti cation of the chemical components in an object. The energy selectivity of the detector is known to have a strong impact in the material decomposition capabilities of an imaging device. Although spectral imaging devices are widely used in conjunc...

متن کامل

Material Decomposition for Energy Resolving Detectors using Weighted Levenberg-Marquardt Optimization

Introduction: Energy resolving X-ray photon counting detectors are able to assign each detected photon to energy bins [1] (Figure 1). This allows the decomposition of an X-ray image into the materials of the acquired object [1, 2], which has potential benefits in angiography. Contrast agent can be extracted without acquiring a mask image, possibly saving dose and avoiding problems with patient ...

متن کامل

Calibration methods influence quantitative material decomposition in photon-counting spectral CT

Photon-counting detectors and nanoparticle contrast agents can potentially enable molecular imaging and material decomposition in computed tomography (CT). Material decomposition has been investigated using both simulated and acquired data sets. However, the effect of calibration methods on material decomposition has not been systematically investigated. Therefore, the objective of this study w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 2013