Negative-ELISA using native and filtrated cystic fluid antigens to rule out cystic echinococcosis.

نویسندگان

  • Paron Dekumyoy
  • Doungrat Riyong
  • Wallop Pakdee
  • Jitra Waikagul
چکیده

An increasing number of cases of echinococcosis in Thailand have been imported, probably native infections and medical transfers. Serodiagnosis is one diagnostic choice for interpreting infections before a further step is done. Due to limited antigen, indirect ELISA has been used as a negative screening test for IgG-detection to rule out echinococcosis. Native hydatid cystic fluid (HCF) antigen from Belgium was used for such testing, in which the ODs-ELISA of samples were compared with those of two positive controls. Subsequently, hydatid cyst fluid from a Thai patient was obtained and the filtrated cyst fluid antigen [(<30)-(>10) kDa, HCF30.10] was prepared to develop negative screening results for the serum samples. By using HCF, three of twenty-four samples resulted in higher ODs-ELISA than the controls. In an attempt to observe the cross-reactivity of this native antigen, IgG-antibodies from many helminthiases cross-reacted and showed high ODs-ELISA. The HCF30.10 Ag was used to develop the test and analyze IgG-antibodies from 5 positive controls (2 parasite-confirmed and 3 positive-serodiagnosed), 183 heterologous cases of 29 diseases and 50 healthy control sera. At a cut-off value of 0.484, the test had 100% sensitivity and 42% specificity. Only Malayan filariasis, onchocercosis, fascioliasis, amebiasis, giardiasis and blastocystosis gave true negatives. Antibodies from nematodiases strongly cross-reacted with HCF30.10 Ag. Nine of fifty (18%) healthy serum controls produced higher OD-values than the cut-off. The routine ELISA uses the HCF30.10 Ag to produce a negative result to echinococcosis, because limited cystic fluid antigen (Thai patient) for test improvement, a lot of cross-reactions and only two protoscolex-positive controls are available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Utility of Recombinant B8/2 Subunit of the Antigen B, Native Antigen, and a Commercial ELISA Kit in the Diagnosis of Human Cystic Echinococcosis

Background: Cystic echinococcosis (CE) is a helminthic disease caused by the larval form of Echinococcus granulosus.  In the present study, the B8/2 subunit of antigen B (AgB) of E. granulosus was expressed in E. coli host and then applied in a diagnostic ELISA set up. Methods: The DNA sequence of AgB8/2 subunit from E. granulosus was extracted from the GenBank and codon-optimized. The target s...

متن کامل

Impairment of Macrophage Presenting Ability and Viability by Echinococcus granulosus Antigens

Background: Despite advances toward an improved understanding of the evasive mechanisms leading to the establishment of cystic echinococcosis, the discovery of specific immunosuppressive mechanisms and related factors are of great interest in the development of an immunotherapeutic approach. Objective: To elucidate immunosuppressive effects of bioactive factors contained in chromatographic frac...

متن کامل

Dot-Elisa for evaluation of hydatid cyst wall, protoscoleces and hydatid cyst fluid antigens in the serodiagnosis of cystic echinococcosis.

The aim of the present study is to evaluate cyst wall and protoscolex as an alternate source of antigen in serodiagnosis of cystic echinococcosis (CE). A total of 90 blood samples, 30 each of confirmed CE cases, disease controls and healthy controls were collected. Dot-ELISA using cyst wall, protoscolex and cyst fluid were used to demonstrate anti-hydatid antibodies. The sensitivity of Dot-ELIS...

متن کامل

Gene cloning, expression and serological evaluation of the 12-kDa antigen-B subunit from Echinococcus granulosus.

A 12-kDa subunit of antigen B from Echinococcus granulosus has recently been cloned, expressed and used in diagnostic ELISA to test human sera for evidence of cystic echinococcosis. The performance of the ELISA based on the recombinant antigen (rAgB) was compared with that of similar assays based on native antigen B (nAgB) or hydatid-cyst fluid. For the preparation of the rAgB, total RNA was ex...

متن کامل

An Easy and Efficient Method for Native and Immunoreactive Echinococcus granulosus Antigen 5 Enrichment from Hydatid Cyst Fluid

BACKGROUND Currently, the serodiagnosis of cystic echinococcosis relies mostly on crude Echinococcus granulosus hydatid cyst fluid as the antigen. Consequently, available immunodiagnostic tests lack standardization of the target antigen and, in turn, this is reflected on poor sensitivity and specificity of the serological diagnosis. METHODOLOGY/PRINCIPAL FINDINGS Here, a chromatographic metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Southeast Asian journal of tropical medicine and public health

دوره 36 Suppl 4  شماره 

صفحات  -

تاریخ انتشار 2005