Transient Analysis of Lossy Nonuniform Transmission Lines Using a Time-step Integration Method
نویسندگان
چکیده
This paper presents an effective numerical method for the transient analysis of lossy transmission lines. With the discretization of the spatial variation of voltages and currents along the transmission lines while remaining the temporal derivatives unchanged, a semidiscrete model is derived from the telegrapher’s equations. The timestep integration method is utilized to derive the recursive scheme of time advancing. A large time step can be used in the computation, meanwhile, its accuracy is guaranteed. Numerical examples are presented to demonstrate the stability and accuracy of the proposed method.
منابع مشابه
Spice Compatible Model for Multiple Coupled Nonuniform Transmission Lines Application in Transient Analysis of VLSI Circuits
An SPICE compatible model for multiple coupled nonuniform lossless transmission lines (TL's) is presented. The method of the modeling is based on the steplines approximation of the nonuniform TLs and quasi-TEM assumptions. Using steplines approximation the system of coupled nonuniform TLs is subdivided into arbitrary large number of coupled uniform lines (steplines) with different characteristi...
متن کاملAnalysis of Coupled or Single Nonuniform Transmission Lines Using Step-by-step Numerical Integration
A method is proposed for analysis of arbitrarily loaded lossy and dispersive nonuniform single or coupled transmission lines. In this method, the transmission lines are subdivided to several uniform sections, at first. Then the voltage and current distributions are obtained using second order step-by-step numerical integration (second order finite difference method). The accuracy of the method ...
متن کاملA Novel Time-domain Integration Method for Transient Analysis of Nonuniform Transmission Lines
This paper presents a precise time-step integration method for transient analysis of lossy nonuniform transmission lines. The spatial discretization in this method is the same to the finite difference time domain (FDTD) algorithm. However, in order to eliminate the Courant condition constraint, the precise integration method is utilized in the time-domain calculation. It gives quasi-exact solut...
متن کاملApplication of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes
In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...
متن کاملAnalysis of Coupled or Single Nonuniform Transmission Lines Using Taylor’s Series Expansion
A method is proposed for analysis of arbitrarily loaded lossy and dispersive nonuniform single or coupled transmission lines. In this method, all the per-unit-length parameters or matrices of the single or coupled lines and also the voltages and currents along the length of them are expanded in Taylor’s series. The solutions of voltages and currents are obtained after finding unknown coefficien...
متن کامل