Sequencing DNA using mass spectrometry for ladder detection.
نویسندگان
چکیده
Sequencing of DNA fragments of 130 and 200 bp using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for DNA ladder detection was demonstrated. With further improvement in mass resolution and detection sensitivity, mass spectrometry shows great promise for routine DNA sequencing in the future.
منابع مشابه
Advanced Detectors for Mass Spectrometry
Mass spectrometry is an instrumental method capable of producing rapid analyses with high mass accuracy. When applied to genome research, it is an attractive alternative to gel electrophoresis. At present, routine DNA analysis by mass spectrometry is seriously constrained to small DNA fragments. Contrasted to other mass spectrometry facilities in which the development of ladder sequencing is em...
متن کاملExopeptidase degradation for the analysis of phosphorylation site in a mono-phosphorylated peptide with matrix-assisted laser desorption/ionization mass spectrometry.
The utility of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) coupled with a peptide ladder sequencing method employing exopeptidase degradation for the analysis of phosphorylation site in a mono-phosphorylated peptide is investigated. MALDI-TOFMS analysis of time-dependent exopeptidase digestion using carboxypeptidase W and aminopeptidase M of the mo...
متن کاملIncreased stability of nucleic acids containing 7-deaza-guanosine and 7-deaza-adenosine may enable rapid DNA sequencing by matrix-assisted laser desorption mass spectrometry.
The use of matrix-assisted laser desorption mass spectrometry (MALDI-MS) has been suggested as an ultrafast readout of Sanger DNA sequencing ladders in a manner analogous to that used with sequencing gels. Currently, a serious limitation of MALDI-MS for the analysis of DNA results from the tendency for oligonucleotides to undergo facile fragmentation in the gas phase. The present study was unde...
متن کاملDNA sequencing using biotinylated dideoxynucleotides and mass spectrometry.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) has been explored widely for DNA sequencing. The major requirement for this method is that the DNA sequencing fragments must be free from alkaline and alkaline earth salts as well as other contaminants for accurately measuring the masses of the DNA fragments. We report here the development of a novel MS DNA sequen...
متن کاملReverse Sanger sequencing of RNA by MALDI-TOF mass spectrometry after solid phase purification.
Several DNA/RNA sequencing strategies have been developed using matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). In the reverse Sanger sequencing approach alpha-thiophosphate-containing NTPs are employed. Sequencing ladders are produced by the subsequent exonuclease cleavage, which is inhibited by the alpha-S-NTP at the 3' terminus. Here the reverse Sanger sequencing of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nucleic acids research
دوره 26 10 شماره
صفحات -